About: Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy.
  • The new RAMARN system for radon volume activity measurement was developed in 2003 and has been in use since then. RAMARN consists of a plastic chamber that is conical cylindrical in shape and about 0,5 l in volume; a bare Kodak LR 115 is located on the bottom of this diffusion chamber. The size was chosen to avoid the influence of deposited RnDP. Kodak has a spectrometric character - the tracks are visualized only for alphas with energies between 1 MeV and 3 MeV that touch the foil; thus the effective volume has a lens shape. The response therefore corresponds to diffused radon and half of 218Po born by radon gas decay. The experiments described below were conducted as one part of a routine methodology control, focused on classifying worker irradiation from natural ionizing radiation sources in show caves and in caves used for speleotherapy. (en)
  • Testování přesnosti měření integrálními detektory RAMARN pro potřeby zpřesnění odhadu dávky pro pracovníky v jeskyních proběhlo ve dvou jeskyních po dobu jednoho roku. Výsledky byly implementovány do novelizace metodiky stanovení dávky. (cs)
Title
  • Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
  • Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors (en)
  • Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory (cs)
skos:prefLabel
  • Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors
  • Effective Dose Assessment for Workers in Caves in the Czech Republic: Experiments with Passive Radon Detectors (en)
  • Stanovení efektivních dávek pro pracovníky jeskyní: experimenty s pasivními detektory (cs)
skos:notation
  • RIV/68407700:21340/08:04150075!RIV09-SUJ-21340___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(JC_12/2006)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 365330
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21340/08:04150075
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • RAMARN detector; radon; continual monitoring; effective dose (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [5355C8EFD7DF]
http://linked.open...i/riv/nazevZdroje
  • Radiation Protection Dosimetry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 130
http://linked.open...iv/tvurceVysledku
  • Thinová, Lenka
  • Burian, I.
http://linked.open...ain/vavai/riv/wos
  • 000259206500012
issn
  • 0144-8420
number of pages
http://localhost/t...ganizacniJednotka
  • 21340
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software