About: Influence of ambient temperature on functioning of dielectric barrier discharge ozone generator.     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Ozone has due to its high relative speed of reactions with chemical and biological species many applications. Generation of ozone by electrical discharge is a complex process, which apart on electrical parameters of the discharge depends also on temperature. The temperature can be associated with the balance of the discharge heat generation and the heat removal. The heat removal from the discharge chamber can be, except of the cooling of the chamber, also affected by input and output of air to or from the discharge chamber. For surface dielectric barrier discharge in air we investigated concentration of produced ozone as a function of average discharge power for temperatures 15 °C and 24 °C, which are the values at which are most frequently functioning commercial ozonizers. We found, that even smal l increase of air temperature from 15°C to 24 °C decreases for particular discharge power ozone concentration to about 60 % of its original value.
  • Ozone has due to its high relative speed of reactions with chemical and biological species many applications. Generation of ozone by electrical discharge is a complex process, which apart on electrical parameters of the discharge depends also on temperature. The temperature can be associated with the balance of the discharge heat generation and the heat removal. The heat removal from the discharge chamber can be, except of the cooling of the chamber, also affected by input and output of air to or from the discharge chamber. For surface dielectric barrier discharge in air we investigated concentration of produced ozone as a function of average discharge power for temperatures 15 °C and 24 °C, which are the values at which are most frequently functioning commercial ozonizers. We found, that even smal l increase of air temperature from 15°C to 24 °C decreases for particular discharge power ozone concentration to about 60 % of its original value. (en)
Title
  • Influence of ambient temperature on functioning of dielectric barrier discharge ozone generator.
  • Influence of ambient temperature on functioning of dielectric barrier discharge ozone generator. (en)
skos:prefLabel
  • Influence of ambient temperature on functioning of dielectric barrier discharge ozone generator.
  • Influence of ambient temperature on functioning of dielectric barrier discharge ozone generator. (en)
skos:notation
  • RIV/68407700:21230/14:00229267!RIV15-TA0-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(TA03010098)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 21310
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/14:00229267
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • dielectric barrier discharge; ozone generator; temperature (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [A2CECCF117AC]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hospodka, Jiří
  • Pekárek, Stanislav
  • Mikeš, Jan
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   