About: Feature Selection for Discrimination of Fractionation Levels in Atrial Electrograms     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Radiofrequency catheter ablation of atrial fibrillation (AF) guided by complex fractionated atrial electrograms (CFAE) is associated with a high AF termination rate in paroxysmal AF, but not in persistent. CFAE does not always identify favorable sites for persistent AF ablation. Studies suggest that only high fractionation level should be used as a target site for ablation. Nonetheless, there are not a standardized criterion to defined fractionation levels. Therefore, a better characterization of the signal is required providing a set of more powerful features that should be extracted from CFAE. Due to the apparent difference among fractionation classes in terms of their stochastic variability, we test time-domain and time-frequency based feature extraction approaches. Also, we carried out the symmetrical uncertainty-based feature selection to determine the most relevant features which improve discrimination of fractionation levels. Obtained results on a tested real electrogram database show that most relevant features in time-domain are related with time intervals and not with amplitudes. Nonetheless, time-frequency features obtained more information from the signal and this representation is likely a better suitable discriminating approach, particularly to detect high fractionated electrograms with a sensitivity and specificity of 83.0% and 93.6%, respectively.
  • Radiofrequency catheter ablation of atrial fibrillation (AF) guided by complex fractionated atrial electrograms (CFAE) is associated with a high AF termination rate in paroxysmal AF, but not in persistent. CFAE does not always identify favorable sites for persistent AF ablation. Studies suggest that only high fractionation level should be used as a target site for ablation. Nonetheless, there are not a standardized criterion to defined fractionation levels. Therefore, a better characterization of the signal is required providing a set of more powerful features that should be extracted from CFAE. Due to the apparent difference among fractionation classes in terms of their stochastic variability, we test time-domain and time-frequency based feature extraction approaches. Also, we carried out the symmetrical uncertainty-based feature selection to determine the most relevant features which improve discrimination of fractionation levels. Obtained results on a tested real electrogram database show that most relevant features in time-domain are related with time intervals and not with amplitudes. Nonetheless, time-frequency features obtained more information from the signal and this representation is likely a better suitable discriminating approach, particularly to detect high fractionated electrograms with a sensitivity and specificity of 83.0% and 93.6%, respectively. (en)
Title
  • Feature Selection for Discrimination of Fractionation Levels in Atrial Electrograms
  • Feature Selection for Discrimination of Fractionation Levels in Atrial Electrograms (en)
skos:prefLabel
  • Feature Selection for Discrimination of Fractionation Levels in Atrial Electrograms
  • Feature Selection for Discrimination of Fractionation Levels in Atrial Electrograms (en)
skos:notation
  • RIV/68407700:21230/14:00224422!RIV15-MSM-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 16597
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/14:00224422
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Bioelectric Phenomena; Catheters; Feature Extraction (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [DFDE515956FF]
http://linked.open...v/mistoKonaniAkce
  • Chicago
http://linked.open...i/riv/mistoVydani
  • Piscataway
http://linked.open...i/riv/nazevZdroje
  • Proceedings of 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Novák, Daniel
  • Bustamante, J.
  • Orozco-Duque, A.
  • Castellanos-Dominguez, G.
  • Martínez-Vargas, J. D.
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/EMBC.2014.6943909
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 978-1-4244-7929-0
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 85 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software