Attributes | Values |
---|
rdf:type
| |
Description
| - This research evaluated an impact of flexion and extension heel pad on surface electromyography of the muscles (Vastus medialis and Vastus lateralis). For signal processing were used Ambu Blue Sensor P, Biomonitor ME6000 MegaWin and software MegaWin 700046 version 3.0. Nineteen healthy subjects of both genders (15 women – 23.5±4.0 years, 4 men – 32.8±11.8 years) volunteered to participate in the study. 19 parameters for evaluation were selected and calculated in MATLAB and statistical evaluation was performed in Microsoft Excel 2007. The ANOVA method followed by post hoc analysis (Tukey method) was chosen for statistical analysis. There were detected only two parameters where there were statistically significant differences (p <0.05) in muscle activity in measurements without reflex heel pad vs. supine reflex heel pad (parameter Median, absolute value of the differences between means: 1.07 μV, p = 0.047) and also in measurements without reflex heel pad vs. pronation reflex heel pad (parameter first spectral moment, absolute value of the difference between means: 1.15 Hz, p = 0.023).
- This research evaluated an impact of flexion and extension heel pad on surface electromyography of the muscles (Vastus medialis and Vastus lateralis). For signal processing were used Ambu Blue Sensor P, Biomonitor ME6000 MegaWin and software MegaWin 700046 version 3.0. Nineteen healthy subjects of both genders (15 women – 23.5±4.0 years, 4 men – 32.8±11.8 years) volunteered to participate in the study. 19 parameters for evaluation were selected and calculated in MATLAB and statistical evaluation was performed in Microsoft Excel 2007. The ANOVA method followed by post hoc analysis (Tukey method) was chosen for statistical analysis. There were detected only two parameters where there were statistically significant differences (p <0.05) in muscle activity in measurements without reflex heel pad vs. supine reflex heel pad (parameter Median, absolute value of the differences between means: 1.07 μV, p = 0.047) and also in measurements without reflex heel pad vs. pronation reflex heel pad (parameter first spectral moment, absolute value of the difference between means: 1.15 Hz, p = 0.023). (en)
|
Title
| - Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint
- Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint (en)
|
skos:prefLabel
| - Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint
- Surface EMG Signal Processing for Evaluation of Isometric Voluntary Extension of the Knee Joint (en)
|
skos:notation
| - RIV/68407700:21230/13:00222694!RIV15-MSM-21230___
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21230/13:00222694
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Surface Electromyography; Signal Processing; Isometric Muscle Contraction (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - BioDat 2013 - Conference on Advanced Methods of Biological Data and Signal Processing
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Jelínek, M.
- Lhotská, Lenka
- Křemen, Václav
- Tichý, M.
- Hrach, K.
- Novotná, Iva
- Cerovsky, Z.
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - České vysoké učení technické v Praze
|
https://schema.org/isbn
| |
http://localhost/t...ganizacniJednotka
| |