About: Fault Tolerant Ethernet Based Network for Time Sensitive Applications in Electrical Power Distribution Systems     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper analyses and experimentally verifies deployment of Ethernet based network technology to enable fault tolerant and timely exchange of data among a number of high voltage protective relays that use proprietary serial communication line to exchange data in real time on a state of its high voltage circuitry facilitating a fast protection switching in case of critical failures. The digital serial signal is first fetched into PCM multiplexer where it is mapped to the corresponding E1 (2 Mbit/s) time division multiplexed signal. Subsequently, the resulting E1 frames are then packetized and sent through Ethernet control LAN to the opposite PCM demultiplexer where the same but reverse processing is done finally sending a signal into the opposite protective relay. The challenge of this setup is to assure very timely delivery of the control information between protective relays even in the cases of potential failures of Ethernet network itself. The tolerance of Ethernet network to faults is assured using widespread per VLAN Rapid Spanning Tree Protocol potentially extended by 1+1 PCM protection as a valuable option.
  • The paper analyses and experimentally verifies deployment of Ethernet based network technology to enable fault tolerant and timely exchange of data among a number of high voltage protective relays that use proprietary serial communication line to exchange data in real time on a state of its high voltage circuitry facilitating a fast protection switching in case of critical failures. The digital serial signal is first fetched into PCM multiplexer where it is mapped to the corresponding E1 (2 Mbit/s) time division multiplexed signal. Subsequently, the resulting E1 frames are then packetized and sent through Ethernet control LAN to the opposite PCM demultiplexer where the same but reverse processing is done finally sending a signal into the opposite protective relay. The challenge of this setup is to assure very timely delivery of the control information between protective relays even in the cases of potential failures of Ethernet network itself. The tolerance of Ethernet network to faults is assured using widespread per VLAN Rapid Spanning Tree Protocol potentially extended by 1+1 PCM protection as a valuable option. (en)
Title
  • Fault Tolerant Ethernet Based Network for Time Sensitive Applications in Electrical Power Distribution Systems
  • Fault Tolerant Ethernet Based Network for Time Sensitive Applications in Electrical Power Distribution Systems (en)
skos:prefLabel
  • Fault Tolerant Ethernet Based Network for Time Sensitive Applications in Electrical Power Distribution Systems
  • Fault Tolerant Ethernet Based Network for Time Sensitive Applications in Electrical Power Distribution Systems (en)
skos:notation
  • RIV/68407700:21230/13:00209385!RIV14-MV0-21230___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(VG20132015104)
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 74763
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/13:00209385
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • E1; PCM; protective switch; RSTP; smart grid; time sensitive applications (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • SK - Slovenská republika
http://linked.open...ontrolniKodProRIV
  • [C83028CF182B]
http://linked.open...i/riv/nazevZdroje
  • Advances in Electrical and Electronic Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 11
http://linked.open...iv/tvurceVysledku
  • Boháč, Leoš
  • Vodrážka, Jiří
issn
  • 1336-1376
number of pages
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 36 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software