| - The created device %22Intelligent Primer Nurse%22 monitors heart rate and user's activity. The device is something like personal wirelless bed side monitor with remote display. Connection to the computer unit is provided by a Bluetooth module. The main aim has been to design a prototype of multi-purpose device suitable for use in senior homes, spas or for lonely seniors. In this device, a special algorithm is implemented for activating alarm in life threatening situation like low or high heart rates or inactivity of user, where a danger of losing consciousness exists. In the future, there will be a possibility to use several %22Primer Nurses%22 for user's multi-monitoring using one central computer.
- The created device %22Intelligent Primer Nurse%22 monitors heart rate and user's activity. The device is something like personal wirelless bed side monitor with remote display. Connection to the computer unit is provided by a Bluetooth module. The main aim has been to design a prototype of multi-purpose device suitable for use in senior homes, spas or for lonely seniors. In this device, a special algorithm is implemented for activating alarm in life threatening situation like low or high heart rates or inactivity of user, where a danger of losing consciousness exists. In the future, there will be a possibility to use several %22Primer Nurses%22 for user's multi-monitoring using one central computer. (en)
|
Title
| - Intelligent Primer Nurse
- Intelligent Primer Nurse (en)
|
skos:prefLabel
| - Intelligent Primer Nurse
- Intelligent Primer Nurse (en)
|
skos:notation
| - RIV/68407700:21230/12:00196961!RIV14-MSM-21230___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...onomickeParametry
| - Development costs: CZK 10,000.-
|
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21230/12:00196961
|
http://linked.open...terniIdentifikace
| |
http://linked.open...riv/jazykVysledku
| |
http://linked.open...vai/riv/kategorie
| |
http://linked.open.../riv/klicovaSlova
| - telemonitoring; vital signs; assistive technologies; Primer 2 (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...echnickeParametry
| - Measured signals: ECG, PPG, accelleration; vigilance button; Outputs: display, remote computer (superordinate system); Communication: BT (BlueTooth)
|