About: Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The paper summarizes basic problems of dimming compatibility of modern LED lamps with the legacy dimming infrastructure. In 2016 the legacy incandescent bulbs are going to be forbidden on the European market and thus it must be replaced by modern and energy efficient solid state lighting. The problems with dimming compatibility appeared. Standards phase-cutting dimmers are widely used in the households and consumers expect the modern lighting to have the same properties as the incandescent bulbs. The legacy dimmers are designed for some minimal load (usually 40 - 60 W) while the modern LED lamps replacements have only about 12 W keeping the 60 W incandescent bulb luminous flux (800 lm). Several different problems must be solved in order to keep the dimming ability, avoid the light flickering and keep the dimmer in the safe operation region. There are two basic dimmer types. The leading edge dimmers that are usually based on triac switch and trailing edge dimmers that use MOSFET switches and electronic control. Both types have its specific demands and need different approach for ensuring the dimming compatibility. New LED driver must be developed in order to be compatible with the legacy dimmers. (en)
  • The paper summarizes basic problems of dimming compatibility of modern LED lamps with the legacy dimming infrastructure. In 2016 the legacy incandescent bulbs are going to be forbidden on the European market and thus it must be replaced by modern and energy efficient solid state lighting. The problems with dimming compatibility appeared. Standards phase-cutting dimmers are widely used in the households and consumers expect the modern lighting to have the same properties as the incandescent bulbs. The legacy dimmers are designed for some minimal load (usually 40 - 60 W) while the modern LED lamps replacements have only about 12 W keeping the 60 W incandescent bulb luminous flux (800 lm). Several different problems must be solved in order to keep the dimming ability, avoid the light flickering and keep the dimmer in the safe operation region. There are two basic dimmer types. The leading edge dimmers that are usually based on triac switch and trailing edge dimmers that use MOSFET switches and electronic control. Both types have its specific demands and need different approach for ensuring the dimming compatibility. New LED driver must be developed in order to be compatible with the legacy dimmers.
Title
  • Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure
  • Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure (en)
skos:prefLabel
  • Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure
  • Dimming Compatibility of 60W Replacement LED Lamps with Legacy Dimming Infrastructure (en)
skos:notation
  • RIV/68407700:21230/12:00192891!RIV13-MSM-21230___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • R
http://linked.open...iv/cisloPeriodika
  • 10
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 131383
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/12:00192891
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Incandescent 60 W replacement; Dimming compatibility; Solid State Lighting; Leading edge; Trailing edge (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • ES - Španělské království
http://linked.open...ontrolniKodProRIV
  • [8FA42D9AC7CB]
http://linked.open...i/riv/nazevZdroje
  • Renewable Energies & Power Quality Journal (RE&PQJ)
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 2012
http://linked.open...iv/tvurceVysledku
  • Bouřa, Adam
  • Husák, Miroslav
issn
  • 2172-038X
number of pages
http://localhost/t...ganizacniJednotka
  • 21230
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software