About: Localizing Metal Electrode from 3D Ultrasound Data Using RANSAC and Intensity Priors     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Není k dispozici (cs)
  • In surgical interventions, miniature metallic tools such as thin electrodes and needles are introduced in tissue. Tracking systems are used to estimate their precise position. In this paper we describe an algorithm that exploits a three-dimensional ultrasound image and raw radio-frequency (RF) signal to determine the position of a thin, metallic electrode in biological tissue. We assume that electrode appears in 3D ultrasound image as a bright, elongated region. To estimate its position, a mathematical model of the region was established. It approximates the electrode axis with a polynomial curve. The voxel intensity distribution near the ray axis was determined from acquired RF signals. The model parameters are estimated by the RANSAC estimator. Finally, the electrode endpoints are located. The method was tested on real ultrasound data of a phantom with a thin tungsten electrode inserted. The results of experiments show that the method is stable even if the data are very noisy.
  • In surgical interventions, miniature metallic tools such as thin electrodes and needles are introduced in tissue. Tracking systems are used to estimate their precise position. In this paper we describe an algorithm that exploits a three-dimensional ultrasound image and raw radio-frequency (RF) signal to determine the position of a thin, metallic electrode in biological tissue. We assume that electrode appears in 3D ultrasound image as a bright, elongated region. To estimate its position, a mathematical model of the region was established. It approximates the electrode axis with a polynomial curve. The voxel intensity distribution near the ray axis was determined from acquired RF signals. The model parameters are estimated by the RANSAC estimator. Finally, the electrode endpoints are located. The method was tested on real ultrasound data of a phantom with a thin tungsten electrode inserted. The results of experiments show that the method is stable even if the data are very noisy. (en)
Title
  • Není k dispozici (cs)
  • Localizing Metal Electrode from 3D Ultrasound Data Using RANSAC and Intensity Priors
  • Localizing Metal Electrode from 3D Ultrasound Data Using RANSAC and Intensity Priors (en)
skos:prefLabel
  • Není k dispozici (cs)
  • Localizing Metal Electrode from 3D Ultrasound Data Using RANSAC and Intensity Priors
  • Localizing Metal Electrode from 3D Ultrasound Data Using RANSAC and Intensity Priors (en)
skos:notation
  • RIV/68407700:21230/05:03117043!RIV06-AV0-21230___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1ET101050403)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 528313
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21230/05:03117043
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • 3D ultrasound; RANSAC; electrode; image-guidance; localization; needle (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...i/riv/kodPristupu
http://linked.open...ontrolniKodProRIV
  • [CC18F31381BF]
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...n/vavai/riv/nosic
  • neuvedeno
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Hlaváč, Václav
  • Kybic, Jan
  • Cachard, C.
  • Barva, Martin
  • Mari, J. M.
http://localhost/t...ganizacniJednotka
  • 21230
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 84 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software