  • Experimental setup with AIRCOOLER_I had been constructed in order to evaluate the performance of vortex tubes, located inside the AIRCOOLER, with high impedance (high pressure drop) structure at the output of the chilled air. The input compressed air (8bara) which was precooled in the water-air heat exchanger was divided into hot and cold streams by the vortex tubes. The cold stream at the temperature of -30°C was cooling down the 1.7m long thin-wall stainless steel tube ID 2mm. The volumetric flow rate of the cooled air was measured by the IST thermal flowmeter which had been calibrated against the precise anemometer TESTO 416. The cooling box was equipped with 3 pressure gauges and number of temperature sensors. The temperature along the stainless-steel tube was measured using 4 Pt1000 sensors. The pressure drop was measured by differential pressure sensor. As a readout for the sensors the ELMB with Kvaser USB/CAN adaptor were employed. For the data storage and visualization the PVSS II SCADA project developed at the Department of Applied Physics was used.
  • Experimental setup with AIRCOOLER_I had been constructed in order to evaluate the performance of vortex tubes, located inside the AIRCOOLER, with high impedance (high pressure drop) structure at the output of the chilled air. The input compressed air (8bara) which was precooled in the water-air heat exchanger was divided into hot and cold streams by the vortex tubes. The cold stream at the temperature of -30°C was cooling down the 1.7m long thin-wall stainless steel tube ID 2mm. The volumetric flow rate of the cooled air was measured by the IST thermal flowmeter which had been calibrated against the precise anemometer TESTO 416. The cooling box was equipped with 3 pressure gauges and number of temperature sensors. The temperature along the stainless-steel tube was measured using 4 Pt1000 sensors. The pressure drop was measured by differential pressure sensor. As a readout for the sensors the ELMB with Kvaser USB/CAN adaptor were employed. For the data storage and visualization the PVSS II SCADA project developed at the Department of Applied Physics was used. (en)
Title
  • SCT mockup for Air cooling
  • SCT mockup for Air cooling (en)
skos:prefLabel
  • SCT mockup for Air cooling
  • SCT mockup for Air cooling (en)
skos:notation
  • RIV/68407700:21220/13:00210960!RIV14-MSM-21220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(LG13009), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • 60000 Kč
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 104164
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/13:00210960
http://linked.open...terniIdentifikace
  • SCT_AirCool2013
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • AIRCOOLER_I; Experimental setup; Cooling box; Data storage and visualization (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [05F469229C47]
http://linked.open.../licencniPoplatek
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • 3m x 0,5m x 0,4m, osazeno senzory a eletronikou
http://linked.open...iv/tvurceVysledku
  • Doubek, Martin
  • Vacek, Václav
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software