  • The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particle image velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room.
  • The main aim of the research work is to describe temperature and velocity fields above the panel radiator fitted with non-standard (or design) covering grids with various flow cross-section and the subsequent effect at an air flow throughout the room. The effect of flow cross-section and shape of openings of panel radiators covering grids at their heat output was determined experimentally. The other experiment dealt with description of velocity field above the covering grid, using the method of particle image velocimetry (PIV). The results are presented in a graphic form as a heat output decrease depending on parameters of the covering grid and in the form of velocity vectors placed in two orthogonal planes. Based on experimentally obtained data, the mathematical model will be verified. Then a computer fluid dynamics (CFD) will be used to simulate both temperature and velocity fields above the panel radiator and in the room. (en)
Title
  • The reduction of convective heat output at panel radiators
  • The reduction of convective heat output at panel radiators (en)
skos:prefLabel
  • The reduction of convective heat output at panel radiators
  • The reduction of convective heat output at panel radiators (en)
skos:notation
  • RIV/68407700:21220/12:00200919!RIV13-MSM-21220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 164495
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/12:00200919
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • free convection; panel radiator; covering grid (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [FF0014480724]
http://linked.open...v/mistoKonaniAkce
  • Praha
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...i/riv/nazevZdroje
  • Sborník STČ 2012
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Heis, Václav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • České vysoké učení technické v Praze. Fakulta strojní
https://schema.org/isbn
  • 978-80-01-04796-5
http://localhost/t...ganizacniJednotka
  • 21220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 118 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software