About: Boiling heat transfer behavior of lead-bismuth-steam-water direct contact two-phase flow     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The boiling heat transfer behavior of lead-bismuth (Pb-Bi)-steam-water direct contact two-phase flow was experimentally investigated. Experimental study was performed using Pb-Bi-steam-water direct contact boiling two-phase flow loop. The heat transfer rate was estimated from data of one-dimensional flow direct contact boiling of water in Pb-Bi. It is assumed in the analysis that film boiling occurs at the surfaces of a small water droplet after water is injected into hot Pb-Bi flow, because of the large temperature difference between water and Pb-Bi (i.e. 493 K and 733 K for injection water and Pb-Bi temperature, respectively). The heat transfer occurs between Pb-Bi and steam without phase change after all water completely evaporates. The overall heat transfer coefficient decreased with the superheat at low injection flow rate and was nearly constant for high injection flow rate.
  • The boiling heat transfer behavior of lead-bismuth (Pb-Bi)-steam-water direct contact two-phase flow was experimentally investigated. Experimental study was performed using Pb-Bi-steam-water direct contact boiling two-phase flow loop. The heat transfer rate was estimated from data of one-dimensional flow direct contact boiling of water in Pb-Bi. It is assumed in the analysis that film boiling occurs at the surfaces of a small water droplet after water is injected into hot Pb-Bi flow, because of the large temperature difference between water and Pb-Bi (i.e. 493 K and 733 K for injection water and Pb-Bi temperature, respectively). The heat transfer occurs between Pb-Bi and steam without phase change after all water completely evaporates. The overall heat transfer coefficient decreased with the superheat at low injection flow rate and was nearly constant for high injection flow rate. (en)
Title
  • Boiling heat transfer behavior of lead-bismuth-steam-water direct contact two-phase flow
  • Boiling heat transfer behavior of lead-bismuth-steam-water direct contact two-phase flow (en)
skos:prefLabel
  • Boiling heat transfer behavior of lead-bismuth-steam-water direct contact two-phase flow
  • Boiling heat transfer behavior of lead-bismuth-steam-water direct contact two-phase flow (en)
skos:notation
  • RIV/68407700:21220/08:00155531!RIV10-MSM-21220___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM6840770020)
http://linked.open...iv/cisloPeriodika
  • 2-6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 358339
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/08:00155531
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • fast breeder reactor; lead-bismuth; drift-flux model (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [50E2EF9BEB1C]
http://linked.open...i/riv/nazevZdroje
  • Progress in Nuclear Energy
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 50
http://linked.open...iv/tvurceVysledku
  • Dostál, Václav
http://linked.open...ain/vavai/riv/wos
  • 000254598500096
http://linked.open...n/vavai/riv/zamer
issn
  • 0149-1970
number of pages
http://localhost/t...ganizacniJednotka
  • 21220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software