  • Není k dispozici (cs)
  • The important characteristic of gas-liquid contactors is the intensity of mass transfer which is characterized by the volumetric mass transfer coefficient - kLa. For the kLa measurement various methods exist (i.e. steady state methods, dynamic pressure method, gassing-out method, dynamic start-up method). One of these methods is dynamic sulfite method. The method is based on simultaneous monitoring of dissolved oxygen and sulfite ions concentrations after an injection of sulfite solution (or other oxygen consuming species) to the batch initially saturated with aerating gas. The concentration of the sulfite oxidized in an analyzed sample of liquid determines the initial oxygen concentration corrected to non-ideal mixing. The volumetric mass transfer coefficient kLa is given by the ratio of the oxygen and sulfite concentration at any known time.
  • The important characteristic of gas-liquid contactors is the intensity of mass transfer which is characterized by the volumetric mass transfer coefficient - kLa. For the kLa measurement various methods exist (i.e. steady state methods, dynamic pressure method, gassing-out method, dynamic start-up method). One of these methods is dynamic sulfite method. The method is based on simultaneous monitoring of dissolved oxygen and sulfite ions concentrations after an injection of sulfite solution (or other oxygen consuming species) to the batch initially saturated with aerating gas. The concentration of the sulfite oxidized in an analyzed sample of liquid determines the initial oxygen concentration corrected to non-ideal mixing. The volumetric mass transfer coefficient kLa is given by the ratio of the oxygen and sulfite concentration at any known time. (en)
Title
  • Není k dispozici (cs)
  • kLa Measurement by Dynamic Sulfite Method in Agitated Vessel
  • kLa Measurement by Dynamic Sulfite Method in Agitated Vessel (en)
skos:prefLabel
  • Není k dispozici (cs)
  • kLa Measurement by Dynamic Sulfite Method in Agitated Vessel
  • kLa Measurement by Dynamic Sulfite Method in Agitated Vessel (en)
skos:notation
  • RIV/68407700:21220/04:02100372!RIV/2005/MSM/212205/N
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 212200008)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 570109
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21220/04:02100372
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Gas-liquid dispersion, mass transfer, agitated vessel, ejector (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...i/riv/kodPristupu
http://linked.open...ontrolniKodProRIV
  • [5E3287127A67]
http://linked.open...i/riv/mistoVydani
  • Praha
http://linked.open...n/vavai/riv/nosic
  • neuvedeno
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Ditl, Pavel
  • Siřínek, Aleš
  • Linek, V.
  • Kordač, M.
http://linked.open...n/vavai/riv/zamer
https://schema.org/isbn
  • 80-86059-40-5
http://localhost/t...ganizacniJednotka
  • 21220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 49 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software