| - This study was concentrated on the assessment of the basic physical properties of polymer gel dosimeter evaluated by NMR. BANG-2 type polymer gel was prepared. The dosimeters were irradiated by 60Co gamma photons and by 4 MV, 6 MV and 18 MV X ray photonsby doses in the range of 0-50 Gy. Multi-echo CPMG sequence was used for the evaluation of T2-relaxation times in irradiated gel dosimeters. The dependence of 1/T2 response of dosimeters was studied on following factors: absorbed dose, energy of applied radiation, temperature during NMR evaluation, time since irradiation to NMR evaluation and strength of the magnetic field. An exponential dependence of 1/T2 response on absorbed dose in the range of 0-50 Gy was observed, in the range 0-10 Gy the data could be fitted by linear function. There was described the dependence of 1/T2 response on: energy, strength of magnetic field and time from irradiation of the dosimeters to NMR evaluation. Increase of gel dosimeter 1/T2 response with the d.
- This study was concentrated on the assessment of the basic physical properties of polymer gel dosimeter evaluated by NMR. BANG-2 type polymer gel was prepared. The dosimeters were irradiated by 60Co gamma photons and by 4 MV, 6 MV and 18 MV X ray photonsby doses in the range of 0-50 Gy. Multi-echo CPMG sequence was used for the evaluation of T2-relaxation times in irradiated gel dosimeters. The dependence of 1/T2 response of dosimeters was studied on following factors: absorbed dose, energy of applied radiation, temperature during NMR evaluation, time since irradiation to NMR evaluation and strength of the magnetic field. An exponential dependence of 1/T2 response on absorbed dose in the range of 0-50 Gy was observed, in the range 0-10 Gy the data could be fitted by linear function. There was described the dependence of 1/T2 response on: energy, strength of magnetic field and time from irradiation of the dosimeters to NMR evaluation. Increase of gel dosimeter 1/T2 response with the d. (en)
|
Title
| - Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter
- Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter (en)
|
skos:prefLabel
| - Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter
- Three-Dimensional Polymer Gel Dosimetry: Basic Physical Properties of the Dosimeter (en)
|
skos:notation
| - RIV/68407700:21220/01:04068253!RIV/2002/MSM/212202/N
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68407700:21220/01:04068253
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Dosimetry; Gel; Polymer; Three-Dimensional (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - GB - Spojené království Velké Británie a Severního Irska
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...ocetUcastnikuAkce
| |
http://linked.open...nichUcastnikuAkce
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| |
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://localhost/t...ganizacniJednotka
| |