  • This paper presents the impact of temperature setpoint and thermal control material on energy use and indoor environmental quality in two different climates using the case study of an office room. The study is conducted in two stages. The first stage focussed on energy consumption for cooling, heating and ventilation of the office whilst maintaining thermal comfort determined from the Predicated Percentage Dissatisfied (PPD) and Predicted Mean Vote (PMV). The second part evaluates the influence of thermal control materials - Vacuum Insulated Panels (VIP) and Phase Change Materials (PCM gypsum plasters) on thermal comfort and energy saving. Comparison of indoor environment condition is performed using a computer simulation tool (ESP-r) and assessed according to the standards requirements in the selected regions. Computer simulation was verified by in situ measurements.
  • This paper presents the impact of temperature setpoint and thermal control material on energy use and indoor environmental quality in two different climates using the case study of an office room. The study is conducted in two stages. The first stage focussed on energy consumption for cooling, heating and ventilation of the office whilst maintaining thermal comfort determined from the Predicated Percentage Dissatisfied (PPD) and Predicted Mean Vote (PMV). The second part evaluates the influence of thermal control materials - Vacuum Insulated Panels (VIP) and Phase Change Materials (PCM gypsum plasters) on thermal comfort and energy saving. Comparison of indoor environment condition is performed using a computer simulation tool (ESP-r) and assessed according to the standards requirements in the selected regions. Computer simulation was verified by in situ measurements. (en)
Title
  • Impact of Temperature Setpoint and Thermal Control Material on Indoor Environment Quality and Energy Use in Office Buildings in Two Climatic Regions
  • Impact of Temperature Setpoint and Thermal Control Material on Indoor Environment Quality and Energy Use in Office Buildings in Two Climatic Regions (en)
skos:prefLabel
  • Impact of Temperature Setpoint and Thermal Control Material on Indoor Environment Quality and Energy Use in Office Buildings in Two Climatic Regions
  • Impact of Temperature Setpoint and Thermal Control Material on Indoor Environment Quality and Energy Use in Office Buildings in Two Climatic Regions (en)
skos:notation
  • RIV/68407700:21110/12:00194066!RIV13-MSM-21110___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(7E09046), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 140700
http://linked.open...ai/riv/idVysledku
  • RIV/68407700:21110/12:00194066
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Energy savings, dynamic simulation, indoor environmental quality, impact of climatic conditions, case study (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [8D7E507D0059]
http://linked.open...v/mistoKonaniAkce
  • Brisbane
http://linked.open...i/riv/mistoVydani
  • Santa Cruz
http://linked.open...i/riv/nazevZdroje
  • Healthy Buildings 2012 - 10th International Conference
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Bartoňová, Jana
  • Kabele, Karel
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • International Society of Indoor Air Quality and Climate - ISIAQ
https://schema.org/isbn
  • 978-1-921897-40-5
http://localhost/t...ganizacniJednotka
  • 21110
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software