About: Real-time X-ray microradiographic imaging and image correlation for local strain mapping in single trabecula under mechanical load     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • X-ray microradiography was used to quantify the strains in loaded human trabecula. Samples of isolated trabeculae from human proximal femur were extracted and glued in a loading machine specially designed for testing of small specimens. The samples were then tested in tension and three-point bending until complete fracture occured. Real-time microradiography in conjunction with digital image correlation has been employed. The samples were irradiated continuously by X-rays. Radiographs were acquired using 0.25s exposure time with hybrid single-photon counting silicon pixel detector Medipix2. Design of the loading device enables for precise control of the applied displacement which is important for the post-yield behavior assessment.
  • X-ray microradiography was used to quantify the strains in loaded human trabecula. Samples of isolated trabeculae from human proximal femur were extracted and glued in a loading machine specially designed for testing of small specimens. The samples were then tested in tension and three-point bending until complete fracture occured. Real-time microradiography in conjunction with digital image correlation has been employed. The samples were irradiated continuously by X-rays. Radiographs were acquired using 0.25s exposure time with hybrid single-photon counting silicon pixel detector Medipix2. Design of the loading device enables for precise control of the applied displacement which is important for the post-yield behavior assessment. (en)
Title
  • Real-time X-ray microradiographic imaging and image correlation for local strain mapping in single trabecula under mechanical load
  • Real-time X-ray microradiographic imaging and image correlation for local strain mapping in single trabecula under mechanical load (en)
skos:prefLabel
  • Real-time X-ray microradiographic imaging and image correlation for local strain mapping in single trabecula under mechanical load
  • Real-time X-ray microradiographic imaging and image correlation for local strain mapping in single trabecula under mechanical load (en)
skos:notation
  • RIV/68378297:_____/11:00367264!RIV12-AV0-68378297
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GAP105/10/2305), Z(AV0Z20710524), Z(MSM6840770040)
http://linked.open...iv/cisloPeriodika
  • 11
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 225869
http://linked.open...ai/riv/idVysledku
  • RIV/68378297:_____/11:00367264
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • pixelated detectors and associated VLSI electronics; X-ray radiography and digital radiography; digital image correlation; human trabecula (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [790CB9E41691]
http://linked.open...i/riv/nazevZdroje
  • Journal of Instrumentation
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 6
http://linked.open...iv/tvurceVysledku
  • Doktor, Tomáš
  • Jiroušek, Ondřej
  • Kytýř, Daniel
  • Zlámal, Petr
  • Jandejsek, I.
http://linked.open...ain/vavai/riv/wos
  • 000298320400007
http://linked.open...n/vavai/riv/zamer
issn
  • 1748-0221
number of pages
http://bibframe.org/vocab/doi
  • 10.1088/1748-0221/6/11/C11007
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 68 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software