Attributes | Values |
---|
rdf:type
| |
Description
| - Calibration source with monoenergetic gamma-ray lines in wide energy range designed for gamma-ray detector energetic calibration and testing has been built. Gamma-rays are obtained from thermal neutron capture, which is a suitable and cost efficient way how to provide discrete gamma-ray lines with energies above 3 MeV with reasonable intensity. With appropriate and interchangeable targets the source can generate different gamma-ray spectra with energy up to 10 MeV. We present the data obtained with neutron capture on chlorine, but other elements with high thermal neutron capture cross-section such as chrome, iron, nickel and titanium can be used as well. As neutron source we employ radionuclide source 241Am-Be with emission rate about 106 neutrons/s. The emitted fast neutrons are moderated by a moderator made of light materials such as graphite, standard water or heavy water. Performance of the source is demonstrated by calibration spectra measured by HPGe and scintillation detectors.
- Calibration source with monoenergetic gamma-ray lines in wide energy range designed for gamma-ray detector energetic calibration and testing has been built. Gamma-rays are obtained from thermal neutron capture, which is a suitable and cost efficient way how to provide discrete gamma-ray lines with energies above 3 MeV with reasonable intensity. With appropriate and interchangeable targets the source can generate different gamma-ray spectra with energy up to 10 MeV. We present the data obtained with neutron capture on chlorine, but other elements with high thermal neutron capture cross-section such as chrome, iron, nickel and titanium can be used as well. As neutron source we employ radionuclide source 241Am-Be with emission rate about 106 neutrons/s. The emitted fast neutrons are moderated by a moderator made of light materials such as graphite, standard water or heavy water. Performance of the source is demonstrated by calibration spectra measured by HPGe and scintillation detectors. (en)
|
Title
| - Wide Energy Range Gamma-Ray Calibration Source
- Wide Energy Range Gamma-Ray Calibration Source (en)
|
skos:prefLabel
| - Wide Energy Range Gamma-Ray Calibration Source
- Wide Energy Range Gamma-Ray Calibration Source (en)
|
skos:notation
| - RIV/68081715:_____/11:00437325!RIV15-AV0-68081715
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/68081715:_____/11:00437325
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - prompt gamma-rays; gamma spectroscopy; detector calibration; thermal neutron capture (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - GB - Spojené království Velké Británie a Severního Irska
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Journal of Instrumentation
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Krejčí, F.
- Kroupa, M.
- Králik, M.
- Owens, A.
- Vobecký, Miloslav
- Šolc, J.
- Quarati, F.
- Pospíšil, S.
- Granja, C. H.
- Janout, Z.
|
http://linked.open...ain/vavai/riv/wos
| |
issn
| |
number of pages
| |
http://bibframe.org/vocab/doi
| - 10.1088/1748-0221/6/11/T11002
|