About: Detection of hydrocarbons using suspended core microstructured optical fiber     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Monitoring of dangerous hydrocarbons is an important issue for both chemical process control in industry and protection of the environment. Vapors of toluene are highly dangerous in low concentrations because of its low explosive limit of 1.2 mol%. Toluene vapors in concentrations lower than the explosive limit can be detected using a fiber optic arrangement containing a short section of suspended core microstructured optical fiber (SC MOF). We prepared the SC MOF for this purpose, with an inner structure consisting of a relatively thin silica core, 2.6 μm in diameter, surrounded by three large cladding holes with radii of 26 μm, which were designed to be large enough for trouble-free analyte flow. It has been shown that a 0.3 m-long SC MOF sensing element can be used for refractometric detection of toluene vapors in low concentrations without using any other adsorption layers. We have experimentally verified the operational reversibility of the SC MOF sensing element in time. A sensitivity of 1.20 0.04 dB/mol% and a detection limit of 0.0079 mol% have been determined for this sensing element. The SC MOF can detect sufficiently low concentrations of toluene vapors to reveal safety risks before the toluene reaches the lower explosive limit
  • Monitoring of dangerous hydrocarbons is an important issue for both chemical process control in industry and protection of the environment. Vapors of toluene are highly dangerous in low concentrations because of its low explosive limit of 1.2 mol%. Toluene vapors in concentrations lower than the explosive limit can be detected using a fiber optic arrangement containing a short section of suspended core microstructured optical fiber (SC MOF). We prepared the SC MOF for this purpose, with an inner structure consisting of a relatively thin silica core, 2.6 μm in diameter, surrounded by three large cladding holes with radii of 26 μm, which were designed to be large enough for trouble-free analyte flow. It has been shown that a 0.3 m-long SC MOF sensing element can be used for refractometric detection of toluene vapors in low concentrations without using any other adsorption layers. We have experimentally verified the operational reversibility of the SC MOF sensing element in time. A sensitivity of 1.20 0.04 dB/mol% and a detection limit of 0.0079 mol% have been determined for this sensing element. The SC MOF can detect sufficiently low concentrations of toluene vapors to reveal safety risks before the toluene reaches the lower explosive limit (en)
Title
  • Detection of hydrocarbons using suspended core microstructured optical fiber
  • Detection of hydrocarbons using suspended core microstructured optical fiber (en)
skos:prefLabel
  • Detection of hydrocarbons using suspended core microstructured optical fiber
  • Detection of hydrocarbons using suspended core microstructured optical fiber (en)
skos:notation
  • RIV/67985882:_____/14:00436361!RIV15-AV0-67985882
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(LD11030), P(LF11001)
http://linked.open...iv/cisloPeriodika
  • October
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 10612
http://linked.open...ai/riv/idVysledku
  • RIV/67985882:_____/14:00436361
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Evanescent wave; Microstructured optical fiber; Refractive index (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CH - Švýcarská konfederace
http://linked.open...ontrolniKodProRIV
  • [6FFA6F3FE42B]
http://linked.open...i/riv/nazevZdroje
  • Sensors and Actuators B - Chemical
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 202
http://linked.open...iv/tvurceVysledku
  • Kašík, Ivan
  • Martan, Tomáš
  • Matějec, Vlastimil
  • Podrazký, Ondřej
  • Aubrecht, Ivo
http://linked.open...ain/vavai/riv/wos
  • 000339994900017
issn
  • 0925-4005
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.snb.2014.04.103
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software