Attributes | Values |
---|
rdf:type
| |
Description
| - Since decades, indoor aerosol models have been introduced to understand the behaviour of indoor aerosols. However, studies about model validation in multi-zone form are very rare because of the lack of high quality and well-controlled measurements. We utilized state-of-the-art measurement and modelling approaches to validate the Multi-Compartment and Size-resolved Indoor Aerosol Model (MC-SIAM) inside a two-zone apartment with natural ventilation. According to the MC-SIAM simulations, the ventilation rates ranged from 0.06 to 0.31 h–1 during closed windows and it was as high as 2.1 h–1 when a window was open; compared to the tracer gases analysis results, the ventilation rate was as high as 0.26 h–1 (closed windows) and 1.7 h–1 (open window). The internal airflow predicted with the MC-SIAM ranged from 9.3 to 11m–3 h (tracer gas analysis 7.6–15m–3 h) when the door between the internal rooms was opened. The methods utilized in this study have proven that indoor aerosol models such as the MC-SIAM are valid to describe the behaviour of indoor aerosol particles inside multi-zone dwellings with the assumption of well-mixed indoor air inside each zone. The next step in indoor aerosol models development should include re-suspension and new particle formation processes.
- Since decades, indoor aerosol models have been introduced to understand the behaviour of indoor aerosols. However, studies about model validation in multi-zone form are very rare because of the lack of high quality and well-controlled measurements. We utilized state-of-the-art measurement and modelling approaches to validate the Multi-Compartment and Size-resolved Indoor Aerosol Model (MC-SIAM) inside a two-zone apartment with natural ventilation. According to the MC-SIAM simulations, the ventilation rates ranged from 0.06 to 0.31 h–1 during closed windows and it was as high as 2.1 h–1 when a window was open; compared to the tracer gases analysis results, the ventilation rate was as high as 0.26 h–1 (closed windows) and 1.7 h–1 (open window). The internal airflow predicted with the MC-SIAM ranged from 9.3 to 11m–3 h (tracer gas analysis 7.6–15m–3 h) when the door between the internal rooms was opened. The methods utilized in this study have proven that indoor aerosol models such as the MC-SIAM are valid to describe the behaviour of indoor aerosol particles inside multi-zone dwellings with the assumption of well-mixed indoor air inside each zone. The next step in indoor aerosol models development should include re-suspension and new particle formation processes. (en)
|
Title
| - Migration of Aerosol Particles inside a Two-Zone Apartment with Natural Ventilation: A Multi-Zone Validation of the Multi-Compartment and Size-Resolved Indoor Aerosol Model
- Migration of Aerosol Particles inside a Two-Zone Apartment with Natural Ventilation: A Multi-Zone Validation of the Multi-Compartment and Size-Resolved Indoor Aerosol Model (en)
|
skos:prefLabel
| - Migration of Aerosol Particles inside a Two-Zone Apartment with Natural Ventilation: A Multi-Zone Validation of the Multi-Compartment and Size-Resolved Indoor Aerosol Model
- Migration of Aerosol Particles inside a Two-Zone Apartment with Natural Ventilation: A Multi-Zone Validation of the Multi-Compartment and Size-Resolved Indoor Aerosol Model (en)
|
skos:notation
| - RIV/67985858:_____/14:00431500!RIV15-GA0-67985858
|
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/67985858:_____/14:00431500
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - ventilation rate; penetration factor; tracer gas (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| - GB - Spojené království Velké Británie a Severního Irska
|
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| - Indoor and Built Environment
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Barták, M.
- Ondráček, Jakub
- Smolík, Jiří
- Hussein, T.
- Džumbová, Lucie
- Mølgaard, B.
- Šťávová, P.
|
http://linked.open...ain/vavai/riv/wos
| |
issn
| |
number of pages
| |
http://bibframe.org/vocab/doi
| |