About: Perioperative haemodynamic monitoring by oesophageal Doppler improves outcome of patients with abdominal aortic aneurysm repair     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • AAA repair is associated with high rate of mortality and morbidity. Oesophageal Doppler (OED) can offer a less invasive cost-effective tool for intraoperative monitoring of haemodynamic changes. The aim of the study was to confirm the benefits of haemodynamic optimisation in patients undergoing AAA repair using OED monitoring. We assumed that haemodynamic parameters of patients with OED would be better optimised; they would probably get more fluids during the operation, and their ICU and hospital stay would be shorter as a result of having fewer postoperative complications and lower mortality. Methods: Seventy patients (Doppler group) who underwent AAA operation in 2003-2008 were matched with 70 patients (control group) operated on AAA in 1998-2002. OED was used to estimate the cardiac output, its variations and fluid management. The administered fluids, length of ICU and hospital stay, frequency of postoperative complications and mortality were compared in Doppler and control groups (Mann-Whitney test, Fisher's exact test). Results: No statistically significant difference was found in preoperative parameters. The Doppler group was administered significantly more crystalloids (p<0.001), colloids (p<0.001), sum-up of fluids (4000 ml vs. 3000 ml; p<0.001) in the perioperative period. The Doppler group had a lower incidence of major serious complications (8 vs. 21; p=0.034) and shorter ICU (4 vs. 6 days; p<0.001) and hospital stay (10 vs. 11 days; p=0.012). Conclusions: The haemodynamic monitoring by oesophageal Doppler can improve the outcome of patients with AAA repair (fewer major complications, shorter ICU and hospital stay)..
  • AAA repair is associated with high rate of mortality and morbidity. Oesophageal Doppler (OED) can offer a less invasive cost-effective tool for intraoperative monitoring of haemodynamic changes. The aim of the study was to confirm the benefits of haemodynamic optimisation in patients undergoing AAA repair using OED monitoring. We assumed that haemodynamic parameters of patients with OED would be better optimised; they would probably get more fluids during the operation, and their ICU and hospital stay would be shorter as a result of having fewer postoperative complications and lower mortality. Methods: Seventy patients (Doppler group) who underwent AAA operation in 2003-2008 were matched with 70 patients (control group) operated on AAA in 1998-2002. OED was used to estimate the cardiac output, its variations and fluid management. The administered fluids, length of ICU and hospital stay, frequency of postoperative complications and mortality were compared in Doppler and control groups (Mann-Whitney test, Fisher's exact test). Results: No statistically significant difference was found in preoperative parameters. The Doppler group was administered significantly more crystalloids (p<0.001), colloids (p<0.001), sum-up of fluids (4000 ml vs. 3000 ml; p<0.001) in the perioperative period. The Doppler group had a lower incidence of major serious complications (8 vs. 21; p=0.034) and shorter ICU (4 vs. 6 days; p<0.001) and hospital stay (10 vs. 11 days; p=0.012). Conclusions: The haemodynamic monitoring by oesophageal Doppler can improve the outcome of patients with AAA repair (fewer major complications, shorter ICU and hospital stay).. (en)
Title
  • Perioperative haemodynamic monitoring by oesophageal Doppler improves outcome of patients with abdominal aortic aneurysm repair
  • Perioperative haemodynamic monitoring by oesophageal Doppler improves outcome of patients with abdominal aortic aneurysm repair (en)
skos:prefLabel
  • Perioperative haemodynamic monitoring by oesophageal Doppler improves outcome of patients with abdominal aortic aneurysm repair
  • Perioperative haemodynamic monitoring by oesophageal Doppler improves outcome of patients with abdominal aortic aneurysm repair (en)
skos:notation
  • RIV/65269705:_____/13:#0002052!RIV14-MZ0-65269705
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(ED2.1.00/03.0072), V
http://linked.open...iv/cisloPeriodika
  • 2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 95809
http://linked.open...ai/riv/idVysledku
  • RIV/65269705:_____/13:#0002052
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • abdominal aortic aneurysm repair; haemodynamic monitoring; oesophageal doppler; outcome (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • SK - Slovenská republika
http://linked.open...ontrolniKodProRIV
  • [54FE5C4BC030]
http://linked.open...i/riv/nazevZdroje
  • Bratislava Medical Journal - Bratislavské lekárske listy
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 114
http://linked.open...iv/tvurceVysledku
  • Šilhart, Zdeněk
http://linked.open...ain/vavai/riv/wos
  • 000314623600008
issn
  • 0006-9248
number of pages
http://bibframe.org/vocab/doi
  • 10.4149/BLL_2013_018
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software