About: Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The work deals with an evaluation of organ doses and effective doses from two verification techniques in image-guided radiotherapy (IGRT): from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections. Both verification techniques help to improve patient setup procedure. On the other hand, using these verification techniques also causes delivering higher doses to healthy organs. Measurements of organ doses were performed at two hospitals using two different imaging systems: On-Board Imager (OBI) and X-ray Volume Imaging (XVI). Organ doses were evaluated in 27 organs for pelvis and head treatment. Measurements of organ doses were performed in an male anthropomorphic Rando phantom by means of thermoluminescent dosimeters (TLDs).Effective doses were calculated from measured organ doses using two ICRP recommendations (ICRP 60 and ICRP 103).
  • The work deals with an evaluation of organ doses and effective doses from two verification techniques in image-guided radiotherapy (IGRT): from kilovoltage (kV) cone-beam CT (CBCT) scans and from pairs of orthogonal kV image projections. Both verification techniques help to improve patient setup procedure. On the other hand, using these verification techniques also causes delivering higher doses to healthy organs. Measurements of organ doses were performed at two hospitals using two different imaging systems: On-Board Imager (OBI) and X-ray Volume Imaging (XVI). Organ doses were evaluated in 27 organs for pelvis and head treatment. Measurements of organ doses were performed in an male anthropomorphic Rando phantom by means of thermoluminescent dosimeters (TLDs).Effective doses were calculated from measured organ doses using two ICRP recommendations (ICRP 60 and ICRP 103). (en)
Title
  • Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)
  • Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT) (en)
skos:prefLabel
  • Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT)
  • Evaluation of Patient Doses from Verification Techniques in Image-Guided Radiotherapy (IGRT) (en)
skos:notation
  • RIV/63108089:_____/09:#0000002!RIV10-SUJ-63108089
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(JC_4/2009)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 313897
http://linked.open...ai/riv/idVysledku
  • RIV/63108089:_____/09:#0000002
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • patient dose; verification; radiotherapy (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [3BB64A145597]
http://linked.open...v/mistoKonaniAkce
  • Mnichov
http://linked.open...i/riv/mistoVydani
  • Heidelberg
http://linked.open...i/riv/nazevZdroje
  • IFMBE Proceedings - World Congress on Medical Physics and Biomedical Engineering
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Dufek, Vladimír
  • Novák, Leoš
  • Horáková, Ivana
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
issn
  • 1680-0737
number of pages
http://purl.org/ne...btex#hasPublisher
  • Springer-Verlag
https://schema.org/isbn
  • 978-3-642-03901-0
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software