Attributes | Values |
---|
rdf:type
| |
rdfs:seeAlso
| |
Description
| - This work reports on the determination of possible degradation products released from PCL films aged in the presence of lipase-type enzyme by means of the gas chromatographic-mass spectrometric analysis. The analysis was performed on HP-6890 gas chromatograph equipped with the mass spectrometric detector HP-5673. HP-5MS column (30 m x 0,25 mm x 0,5 mikm, film of bonded 5 % phenyl, 95 % dimethylpolysiloxane, Hewlett-Packard, Waldbronn, Germany) was used. PCL substrate in the film form (Mn = 19 300 g/mol) was added to a phosphate buffer system with pH = 7 containing 0,05 mg ml-1 Aspergillus sp. lipase with the initial enzymatic activity of 0,3 mmol min-1 ml-1. The degradation experiments were carried out for 42 days at 37 °C. For analyses purpose, the aliquots of buffer solution, used in degradation tests, were withdrawn in certain intervals and extracted with dichloromethane. Subsequently, the presence of e-caprolactone was confirmed in the extracts. The decrease in the amount of e-caprolactone (18,1 -- 0,65 mikg.g-1) was observed during the degradation period.
- This work reports on the determination of possible degradation products released from PCL films aged in the presence of lipase-type enzyme by means of the gas chromatographic-mass spectrometric analysis. The analysis was performed on HP-6890 gas chromatograph equipped with the mass spectrometric detector HP-5673. HP-5MS column (30 m x 0,25 mm x 0,5 mikm, film of bonded 5 % phenyl, 95 % dimethylpolysiloxane, Hewlett-Packard, Waldbronn, Germany) was used. PCL substrate in the film form (Mn = 19 300 g/mol) was added to a phosphate buffer system with pH = 7 containing 0,05 mg ml-1 Aspergillus sp. lipase with the initial enzymatic activity of 0,3 mmol min-1 ml-1. The degradation experiments were carried out for 42 days at 37 °C. For analyses purpose, the aliquots of buffer solution, used in degradation tests, were withdrawn in certain intervals and extracted with dichloromethane. Subsequently, the presence of e-caprolactone was confirmed in the extracts. The decrease in the amount of e-caprolactone (18,1 -- 0,65 mikg.g-1) was observed during the degradation period. (en)
|
Title
| - Gas chromatographic-mas spectrometric determination of low molecular products formed during exposition of polycaprolactone to aspergillus-lipase
- Gas chromatographic-mas spectrometric determination of low molecular products formed during exposition of polycaprolactone to aspergillus-lipase (en)
|
skos:prefLabel
| - Gas chromatographic-mas spectrometric determination of low molecular products formed during exposition of polycaprolactone to aspergillus-lipase
- Gas chromatographic-mas spectrometric determination of low molecular products formed during exposition of polycaprolactone to aspergillus-lipase (en)
|
skos:notation
| - RIV/62156489:43210/11:00182658!RIV12-MSM-43210___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/62156489:43210/11:00182658
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - PCL; gas chromatography - mass spectrometry (gc-ms); polycaprolactone; analysis (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...i/riv/kodPristupu
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Omelková, Jiřina
- Hermanová, Soňa
- Voběrková, Stanislava
- Helánová, Valerie
- Kulštejnová, Lucie
|
http://localhost/t...ganizacniJednotka
| |