About: Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns. Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any pow
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns. Basic operation principles of a lightweight, low power, low cost, portable ion chromatograph utilizing open tubular ion chromatography in capillary columns coated with multi-layer polymeric stationary phases are demonstrated. A minimalistic configuration of a portable IC instrument was developed that does not require any chromatographic eluent delivery system, nor sample injection device as it uses gravity-based eluent flow and hydrodynamic sample injection adopted from capillary electrophoresis. As a detection device, an inexpensive commercially available capacitance sensor is used that has been shown to be a suitable substitute for contactless conductivity detection in capillary separation systems. The built-in temperature sensor allows for baseline drift correction typically encountered in conductivity/capacitance measurements without thermostating device. The whole instrument does not require any pow (en)
Title
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns (en)
skos:prefLabel
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns
  • Portable, lightweight, low power, ion chromatographic system with open tubular capillary columns (en)
skos:notation
  • RIV/62156489:43210/10:00159341!RIV11-GA0-43210___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/07/0983), V
http://linked.open...iv/cisloPeriodika
  • 31
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 280048
http://linked.open...ai/riv/idVysledku
  • RIV/62156489:43210/10:00159341
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • separation of cations; portable ion chromatograph; ion chromatography (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [07F79921B417]
http://linked.open...i/riv/nazevZdroje
  • Journal of Chromatography A
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 1217
http://linked.open...iv/tvurceVysledku
  • Kubáň, Vlastimil
  • Kubáň, Petr
  • Pelcová, Pavlína
  • Kiplagat, Isaac Kipkoech
issn
  • 0021-9673
number of pages
http://localhost/t...ganizacniJednotka
  • 43210
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software