About: Rapid Speciation of Inorganic Se(IV) and Se(VI) Compounds by Flow Injection-Capillary Electrophoresis System with Contactless Conductometric Detection and Hydrostatic Pressure Generated Flow.     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Flow injection -- capillary electrophoresis system with contactless conductivity detection and hydrostatic pressure generated flow was used for fast and sensitive speciation of Se(IV) and Se(VI) and simultaneous determination of other common inorganic anions. The sample throughput was 25 samples per hour using the background electrolyte solution containing 8.75 mM L-histidine adjusted to pH 4.00 with acetic acid. The repeatability of peak areas (n = 8) was better than 1.41% and The limits of detection were 190 mgL-1 and 7.5 mgL-1 for Se(IV) and Se(VI), respectively. The interference from carbonate, typically present in water samples, was eliminated by using a low pH electrolyte in which carbonate is uncharged and migrates at the EOF front. The method was applied to the analysis of Se(IV) and Se(VI) in soil samples that were spiked with both selenium species and the results for recovery of both selenium species were in good agreement with their introduced concentrations. The method is suitable for the
  • Flow injection -- capillary electrophoresis system with contactless conductivity detection and hydrostatic pressure generated flow was used for fast and sensitive speciation of Se(IV) and Se(VI) and simultaneous determination of other common inorganic anions. The sample throughput was 25 samples per hour using the background electrolyte solution containing 8.75 mM L-histidine adjusted to pH 4.00 with acetic acid. The repeatability of peak areas (n = 8) was better than 1.41% and The limits of detection were 190 mgL-1 and 7.5 mgL-1 for Se(IV) and Se(VI), respectively. The interference from carbonate, typically present in water samples, was eliminated by using a low pH electrolyte in which carbonate is uncharged and migrates at the EOF front. The method was applied to the analysis of Se(IV) and Se(VI) in soil samples that were spiked with both selenium species and the results for recovery of both selenium species were in good agreement with their introduced concentrations. The method is suitable for the (en)
  • Flow injection -- capillary electrophoresis system with contactless conductivity detection and hydrostatic pressure generated flow was used for fast and sensitive speciation of Se(IV) and Se(VI) and simultaneous determination of other common inorganic anions. The sample throughput was 25 samples per hour using the background electrolyte solution containing 8.75 mM L-histidine adjusted to pH 4.00 with acetic acid. The repeatability of peak areas (n = 8) was better than 1.41% and The limits of detection were 190 mgL-1 and 7.5 mgL-1 for Se(IV) and Se(VI), respectively. The interference from carbonate, typically present in water samples, was eliminated by using a low pH electrolyte in which carbonate is uncharged and migrates at the EOF front. The method was applied to the analysis of Se(IV) and Se(VI) in soil samples that were spiked with both selenium species and the results for recovery of both selenium species were in good agreement with their introduced concentrations. The method is suitable for the (cs)
Title
  • Rapid Speciation of Inorganic Se(IV) and Se(VI) Compounds by Flow Injection-Capillary Electrophoresis System with Contactless Conductometric Detection and Hydrostatic Pressure Generated Flow.
  • Rapid Speciation of Inorganic Se(IV) and Se(VI) Compounds by Flow Injection-Capillary Electrophoresis System with Contactless Conductometric Detection and Hydrostatic Pressure Generated Flow. (en)
  • Rychlá speciace anorganických forem selenu (IV)a (VI) pomocí FI-CE/CZE (cs)
skos:prefLabel
  • Rapid Speciation of Inorganic Se(IV) and Se(VI) Compounds by Flow Injection-Capillary Electrophoresis System with Contactless Conductometric Detection and Hydrostatic Pressure Generated Flow.
  • Rapid Speciation of Inorganic Se(IV) and Se(VI) Compounds by Flow Injection-Capillary Electrophoresis System with Contactless Conductometric Detection and Hydrostatic Pressure Generated Flow. (en)
  • Rychlá speciace anorganických forem selenu (IV)a (VI) pomocí FI-CE/CZE (cs)
skos:notation
  • RIV/62156489:43210/04:00000820!RIV/2005/MSM/432105/N
http://linked.open.../vavai/riv/strany
  • 378;382
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 432100001)
http://linked.open...iv/cisloPeriodika
  • 5
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 583561
http://linked.open...ai/riv/idVysledku
  • RIV/62156489:43210/04:00000820
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • FI-CE/CZE;selenium;speciation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • DE - Spolková republika Německo
http://linked.open...ontrolniKodProRIV
  • [F2673590FD33]
http://linked.open...i/riv/nazevZdroje
  • Analytical and bioanalytical chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 378
http://linked.open...iv/tvurceVysledku
  • Kubáň, Pavel
  • Kubáň, Vlastimil
  • Kubáň, Petr
http://linked.open...n/vavai/riv/zamer
issn
  • 1618-2642
number of pages
http://localhost/t...ganizacniJednotka
  • 43210
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software