  • The aim of this paper is to compare the glaucoma diagnostic reliability of two optic disc parameters: the relative cup area size determined by the Heidelberg retina tomography and the relative pallor area size determined by the proposed algorithm of the optic disc image analysis. Both parameters were measured for 240 normal healthy eyes and 240 glaucomatous eyes. The diagnostic reliability of studied parameters were compared using normalized distance d of their statistical distributions obtained for normal healthy and glaucomatous eyes and by comparison of area sizes under their ROC (Receiver Operating Characteristic) curves. The normalized distances were 2.19 or 1.73 and the area sizes under ROC curves were 0.95 or 0.89 for relative cup or pallor area size. Both considered relative parameters are significantly influenced by the glaucoma and can be used in its diagnostics. The designed pallor analysis is less diagnostic reliable than the analysis of the cup
  • The aim of this paper is to compare the glaucoma diagnostic reliability of two optic disc parameters: the relative cup area size determined by the Heidelberg retina tomography and the relative pallor area size determined by the proposed algorithm of the optic disc image analysis. Both parameters were measured for 240 normal healthy eyes and 240 glaucomatous eyes. The diagnostic reliability of studied parameters were compared using normalized distance d of their statistical distributions obtained for normal healthy and glaucomatous eyes and by comparison of area sizes under their ROC (Receiver Operating Characteristic) curves. The normalized distances were 2.19 or 1.73 and the area sizes under ROC curves were 0.95 or 0.89 for relative cup or pallor area size. Both considered relative parameters are significantly influenced by the glaucoma and can be used in its diagnostics. The designed pallor analysis is less diagnostic reliable than the analysis of the cup (en)
Title
  • Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics
  • Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics (en)
skos:prefLabel
  • Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics
  • Comparison of Reliability of the Eye Optic Disc Cup and Pallor Areas in Glaucoma Diagnostics (en)
skos:notation
  • RIV/61989592:15310/13:33144447!RIV14-MSM-15310___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • S1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 66293
http://linked.open...ai/riv/idVysledku
  • RIV/61989592:15310/13:33144447
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • image analysis; laser scanning tomography; glaucoma; pallor; Cup (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • HR - Chorvatská republika
http://linked.open...ontrolniKodProRIV
  • [D96BD5EFB5CC]
http://linked.open...i/riv/nazevZdroje
  • Collegium Antropologicum
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 37
http://linked.open...iv/tvurceVysledku
  • Wagner, Jaroslav
  • Pluháček, František
http://linked.open...ain/vavai/riv/wos
  • 000318456800012
issn
  • 0350-6134
number of pages
http://localhost/t...ganizacniJednotka
  • 15310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software