| - A novel long drop time mercury electrode has been constructed from common fused-silica capillary (50um I.D., 360um E.D.). Proposed device provides reproducible mercury drops with typical lifetime 40-120 s. The electrode was used for a set of electrocapillary measurements aimed at determination of critical micelle concentration of anionic surfactants by a convection controlled drop-time technique. A critical micelle concentration of sodium dodecyl sulfate 5.6+-0.4mmolL?1 and 4.3+-0.4mmolL?1 were obtained in 1mmolL?1 and 5mmolL?1 phosphate buffer (pH 7.0), respectively. The values were comparable to those obtained from conductometric measurements under the same conditions (7.0+-0.1mmolL?1 and 5.2+-0.1mmolL?1, respectively) and the difference was explained in accordance with theory of hemi-micelle formation.
- A novel long drop time mercury electrode has been constructed from common fused-silica capillary (50um I.D., 360um E.D.). Proposed device provides reproducible mercury drops with typical lifetime 40-120 s. The electrode was used for a set of electrocapillary measurements aimed at determination of critical micelle concentration of anionic surfactants by a convection controlled drop-time technique. A critical micelle concentration of sodium dodecyl sulfate 5.6+-0.4mmolL?1 and 4.3+-0.4mmolL?1 were obtained in 1mmolL?1 and 5mmolL?1 phosphate buffer (pH 7.0), respectively. The values were comparable to those obtained from conductometric measurements under the same conditions (7.0+-0.1mmolL?1 and 5.2+-0.1mmolL?1, respectively) and the difference was explained in accordance with theory of hemi-micelle formation. (en)
|
Title
| - A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration
- A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration (en)
|
skos:prefLabel
| - A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration
- A novel fused-silica capillary dropping mercury electrode with long drop-time and its application on determination of critical micelle concentration (en)
|
skos:notation
| - RIV/61989592:15310/11:33117300!RIV12-MSM-15310___
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...iv/cisloPeriodika
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61989592:15310/11:33117300
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Electrocapillary measurement, Dropping mercury electrode, Critical micelle concentration, Fused-silica capillary, Sodium dodecyl sulfate (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...odStatuVydavatele
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...i/riv/nazevZdroje
| |
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...v/svazekPeriodika
| |
http://linked.open...iv/tvurceVysledku
| - Barták, Petr
- Müller, Lukáš
- Skopalová, Jana
- Součková, Jitka
- Vymětalíková, Michaela
|
http://linked.open...ain/vavai/riv/wos
| |
http://linked.open...n/vavai/riv/zamer
| |
issn
| |
number of pages
| |
http://bibframe.org/vocab/doi
| - 10.1016/j.talanta.2010.12.050
|