About: Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • One link of the production chain of ironworks is sintering. There is a preparation of the ore charge in it, which is transported to the next conveyor system by the bucket excavator. The paper presents results of experimental measurements performed on the bucket loader drive, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of the drive connection. This paper also provides a comparison of levels of monitored voltage characteristics obtained by the measurements to simulated ones, and to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2: Environment – Compatibility levels in industrial plants for low-frequency conducted disturbances. Both measurement and simulation confirmed that used input reactor for harmonic mitigation in the drive structure has only very low impact on the level of drawn current and supply voltage distortion. In this paper a simulation is also done for a possibility of using broadband passive harmonic filters to reduce current and voltage distortion. The results show their significant impact on improving quality of drawn current by the drive and supply voltage at the point of its connection.
  • One link of the production chain of ironworks is sintering. There is a preparation of the ore charge in it, which is transported to the next conveyor system by the bucket excavator. The paper presents results of experimental measurements performed on the bucket loader drive, an analysis of the drive disturbance and an assessment of electrical energy quality at the point of the drive connection. This paper also provides a comparison of levels of monitored voltage characteristics obtained by the measurements to simulated ones, and to their compatibility levels stated in the standard ČSN EN 61000-2-4 ed. 2: Environment – Compatibility levels in industrial plants for low-frequency conducted disturbances. Both measurement and simulation confirmed that used input reactor for harmonic mitigation in the drive structure has only very low impact on the level of drawn current and supply voltage distortion. In this paper a simulation is also done for a possibility of using broadband passive harmonic filters to reduce current and voltage distortion. The results show their significant impact on improving quality of drawn current by the drive and supply voltage at the point of its connection. (en)
Title
  • Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard
  • Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard (en)
skos:prefLabel
  • Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard
  • Analysis and Simulation of Disturbance of Excavator in Sintering Ore-Storage Yard (en)
skos:notation
  • RIV/61989100:27240/14:86090040!RIV15-MSM-27240___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 2601
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27240/14:86090040
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • simulation; drive; disturbance; broadband passive harmonic filter; bucket excavator (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [250A0E40054C]
http://linked.open...v/mistoKonaniAkce
  • Brno
http://linked.open...i/riv/mistoVydani
  • Danvers
http://linked.open...i/riv/nazevZdroje
  • EPE 2014 : Electric Power Engineering 2014 : 15th International Scientific Conference : Brno, May 12th to May 14th, 2014
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kocman, Stanislav
  • Hrubý, Tomáš
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/EPE.2014.6839425
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 978-1-4799-3806-3
http://localhost/t...ganizacniJednotka
  • 27240
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 48 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software