About: Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Need of blood pressure measurement is usable in wide spectrum of applications from physicians offices to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are measurement devices which need to be in contact with human body (hand or foot mainly). Further they allow only one measurement per several minutes interval (typically 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measures a blood pressure during a long time period and sends this information to remote operator?s stations. In this station the analysis of receiving video data is made for several types of usage. In current state we develop a small device to scan a video or a set of images with the NIR (Near Infra Red) CCD camera. The video data are transferred by wireless connection to the computer where they are analyzed.
  • Need of blood pressure measurement is usable in wide spectrum of applications from physicians offices to home care applications. Many types of blood pressure measurement devices can be bought in electronics shops. All such devices are measurement devices which need to be in contact with human body (hand or foot mainly). Further they allow only one measurement per several minutes interval (typically 10 minutes). Our goal is to develop a small device for noninvasive continuous measurement of blood pressure. This device must be a small battery powered embedded system which measures a blood pressure during a long time period and sends this information to remote operator?s stations. In this station the analysis of receiving video data is made for several types of usage. In current state we develop a small device to scan a video or a set of images with the NIR (Near Infra Red) CCD camera. The video data are transferred by wireless connection to the computer where they are analyzed. (en)
Title
  • Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients
  • Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients (en)
skos:prefLabel
  • Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients
  • Noninvasive Continuous Blood Pressure Measurement and GPS Position Monitoring of Patients (en)
skos:notation
  • RIV/61989100:27240/09:00021366!RIV12-MSM-27240___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1M0567), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 329697
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27240/09:00021366
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Analyzer; Mobile Device; Pressure; Blood (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [D0A3F971F5B0]
http://linked.open...v/mistoKonaniAkce
  • Anchorage, USA
http://linked.open...i/riv/mistoVydani
  • NEW YORK
http://linked.open...i/riv/nazevZdroje
  • 2009 IEEE 70TH VEHICULAR TECHNOLOGY CONFERENCE FALL, VOLS 1-4
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Frischer, Robert
  • Krejcar, Ondřej
  • Slanina, Zdeněk
  • Silber, Petr
  • Štambach, Jan
http://linked.open...vavai/riv/typAkce
http://linked.open...ain/vavai/riv/wos
  • 000280580400001
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • IEEE, 345 E 47TH ST
https://schema.org/isbn
  • 978-1-4244-2514-3
http://localhost/t...ganizacniJednotka
  • 27240
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software