| - The aim of this work is different methods and realizations of telemetric data transfer from pulse oximeter Criticare 504 USP to computer. This device takes the plethysmographycal curve, ECG curve, saturation and beat. Plethysmography is diagnostic method, which serves for rating of well perfused tissue and gives information about working and reactivity of vessels. Finger plethysmography focus on acquiring records of pulse waves during hearth action by sensor, which is located on the end of finger. In present time, the plethysmography is classic non-invasive method for examinee of vessels, which is used in angiology and also in industrial medicine.
- The aim of this work is different methods and realizations of telemetric data transfer from pulse oximeter Criticare 504 USP to computer. This device takes the plethysmographycal curve, ECG curve, saturation and beat. Plethysmography is diagnostic method, which serves for rating of well perfused tissue and gives information about working and reactivity of vessels. Finger plethysmography focus on acquiring records of pulse waves during hearth action by sensor, which is located on the end of finger. In present time, the plethysmography is classic non-invasive method for examinee of vessels, which is used in angiology and also in industrial medicine. (en)
|
Title
| - Telemetry of pletysmographycal record and its processing
- Telemetry of pletysmographycal record and its processing (en)
|
skos:prefLabel
| - Telemetry of pletysmographycal record and its processing
- Telemetry of pletysmographycal record and its processing (en)
|
skos:notation
| - RIV/61989100:27240/03:00008318!RIV/2004/GA0/272404/N
|
http://linked.open.../vavai/riv/strany
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/61989100:27240/03:00008318
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - Pulse wave, Pulse oximeter, Pletysmograph, ECG, Beat, Saturation, Communication, RS-232 interface, Microprocessor (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Programmable Devices and Systems 2003
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...ocetUcastnikuAkce
| |
http://linked.open...nichUcastnikuAkce
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Penhaker, Marek
- Semkovič, J.
|