  • The contribution analysis process on the water-air interface. A dynamic equilibrium on the phase interface water-air is established that means the interchange of radon is in both directions until the finite ratio of concentrations is established. The finite ratio is given by Henry constant. This equilibrium is important for the radon separation from water. Among the important factors there are radon diffusion coefficients in water and air, whose relatively small amount forces us to use convection in both mediums as well. Many techniques must face the problem of free surface size and therefore many ways to solve this problem were searched. One of the acceptable possibilities seems to be the selective membranes, in heterogeneous as well as homogenous structure. The costs for radon removal from small drinking water sources, respectively for buying the appropriate equipment must be optimized regarding the health risk resulting from exposure to radon. In order to decrease the radiation that is affined with the usage of drinking water it is possible to eliminate radon before the drinking water is brought to the building (e. g. aeration tower). Due to economic reasons this is possible only with large sources for collective supply. For small water sources mostly high costs for buying radon eliminating equipment are not acceptable at present.
  • The contribution analysis process on the water-air interface. A dynamic equilibrium on the phase interface water-air is established that means the interchange of radon is in both directions until the finite ratio of concentrations is established. The finite ratio is given by Henry constant. This equilibrium is important for the radon separation from water. Among the important factors there are radon diffusion coefficients in water and air, whose relatively small amount forces us to use convection in both mediums as well. Many techniques must face the problem of free surface size and therefore many ways to solve this problem were searched. One of the acceptable possibilities seems to be the selective membranes, in heterogeneous as well as homogenous structure. The costs for radon removal from small drinking water sources, respectively for buying the appropriate equipment must be optimized regarding the health risk resulting from exposure to radon. In order to decrease the radiation that is affined with the usage of drinking water it is possible to eliminate radon before the drinking water is brought to the building (e. g. aeration tower). Due to economic reasons this is possible only with large sources for collective supply. For small water sources mostly high costs for buying radon eliminating equipment are not acceptable at present. (en)
Title
  • RADON ON THE PHASE INTERFACE WATER-AIR AND THE SEPARATION OF RADON FROM DRINKING WATER WITH THE POSSIBILITY OF SEMIPERMEABLE MEMBRANES UTILIZATION
  • RADON ON THE PHASE INTERFACE WATER-AIR AND THE SEPARATION OF RADON FROM DRINKING WATER WITH THE POSSIBILITY OF SEMIPERMEABLE MEMBRANES UTILIZATION (en)
skos:prefLabel
  • RADON ON THE PHASE INTERFACE WATER-AIR AND THE SEPARATION OF RADON FROM DRINKING WATER WITH THE POSSIBILITY OF SEMIPERMEABLE MEMBRANES UTILIZATION
  • RADON ON THE PHASE INTERFACE WATER-AIR AND THE SEPARATION OF RADON FROM DRINKING WATER WITH THE POSSIBILITY OF SEMIPERMEABLE MEMBRANES UTILIZATION (en)
skos:notation
  • RIV/61989100:27200/07:86081866!RIV12-MPO-27200___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(2A-1TP1/044)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 446338
http://linked.open...ai/riv/idVysledku
  • RIV/61989100:27200/07:86081866
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • radon, water, membranes, water-air interface (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [F1D74E071149]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Danihelka, Pavel
  • Kopecká, Lenka
  • Švec, Jiří
  • Suchánková, Jana
  • Uhrová, Ilona
http://localhost/t...ganizacniJednotka
  • 27200
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 47 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software