  • The aim of this work was to compare body fat measured by Dual X-Ray Absorptiometry (DXA, Hologic Discovery W) and by Bioelectrical Impedance Analysis (BIA, Nutriguard M) in obese women with indicated sleeve gastrectomy. The sample consisted of 67 women (27 to 68 years old). They underwent body weight and height, waist and hip measurement and the BMI was calculated. The correction equation for conversion of body fat BIA was created from selected parameters, so that results of this method were comparable to the results of DXA reference method. BMI was 42.3 ? 5.6 kg/m2. Average amount of fat was 48.8 ? 4 % (DXA). Fat determined by BIA was on average 3.8 % lower (p <0.001). Correction formula for the conversion of body fat percentage observed by BIA correlated with the DXA (r = 0,791) and showed the same results as the DXA (p = 0.808). (en)
  • Cílem této práce bylo porovnání tělesného tuku zjišťovaného pomocí metod duální rentgenové absorpciometrie (DXA, Hologic Discovery W) a bioelektrické impedance (BIA, Nutriguard M) u obézních žen indikovaných ke sleeve gastrektomii. Soubor tvořilo celkem 67 žen (27 až 68 let). Byla měřena tělesná hmotnost a výška, obvod pasu a boků a vypočítán BMI. Byla vytvořena korekční rovnice pro přepočet procenta tělesného tuku stanoveného pomocí BIA tak, aby výsledky této metody odpovídaly referenční metodě DXA. Metodou BIA byly dosaženy hodnoty v průměru o 3,8 % tuku nižší (p < 0,001). Hodnoty BIA přepočítané pomocí korekční rovnice korelovaly s DXA (r = 0,791), v absolutních hodnotách se výsledky prakticky nelišily (p = 0,808).
  • Cílem této práce bylo porovnání tělesného tuku zjišťovaného pomocí metod duální rentgenové absorpciometrie (DXA, Hologic Discovery W) a bioelektrické impedance (BIA, Nutriguard M) u obézních žen indikovaných ke sleeve gastrektomii. Soubor tvořilo celkem 67 žen (27 až 68 let). Byla měřena tělesná hmotnost a výška, obvod pasu a boků a vypočítán BMI. Byla vytvořena korekční rovnice pro přepočet procenta tělesného tuku stanoveného pomocí BIA tak, aby výsledky této metody odpovídaly referenční metodě DXA. Metodou BIA byly dosaženy hodnoty v průměru o 3,8 % tuku nižší (p < 0,001). Hodnoty BIA přepočítané pomocí korekční rovnice korelovaly s DXA (r = 0,791), v absolutních hodnotách se výsledky prakticky nelišily (p = 0,808). (cs)
Title
  • Comparison of DXA and BIA in obese women indicated a sleeve gastrectomy - pilot study (en)
  • Srovnání metod DXA a BIA u obézních žen indikovaných ke sleeve gastrektomii - pilotní studie
  • Srovnání metod DXA a BIA u obézních žen indikovaných ke sleeve gastrektomii - pilotní studie (cs)
skos:prefLabel
  • Comparison of DXA and BIA in obese women indicated a sleeve gastrectomy - pilot study (en)
  • Srovnání metod DXA a BIA u obézních žen indikovaných ke sleeve gastrektomii - pilotní studie
  • Srovnání metod DXA a BIA u obézních žen indikovaných ke sleeve gastrektomii - pilotní studie (cs)
skos:notation
  • RIV/61988987:17110/11:A13013LU!RIV13-MSM-17110___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 12
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 231761
http://linked.open...ai/riv/idVysledku
  • RIV/61988987:17110/11:A13013LU
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • bioelectrical impedance analysis; DXA; sleeve gastrectomy; body composition; body fat percentage (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [2AF9F0182528]
http://linked.open...i/riv/nazevZdroje
  • Praktický lékař
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 91
http://linked.open...iv/tvurceVysledku
  • Jirák, Zdeněk
  • Bužga, Marek
  • Chroboková, Adéla
  • Zavadilová, Vladislava
issn
  • 0032-6739
number of pages
http://localhost/t...ganizacniJednotka
  • 17110
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software