About: Quantification in MALDI-TOF mass spectrometry of modified polymers     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • MALDI-TOF MS quantification is hampered by the poor reproducibility and molecular-mass and compositional discrimination. The use of an internal standard increases reproducibility and allows a calibration curve to be constructed. With synthetic polymers, the method requires a polymer of the same molecular mass distribution and composition as the analyte. When the content of the precursor polymer in a modified polymer is sought, the pure precursor is usually available and the modified polymer can serve as an internal standard. The method has to be combined with that of standard addition and the precursor polymer added directly to the sample. The experiments with simulated modified polymers revealed the signal-intensity ratio not proportional to the concentrations ratio. Thus, the basic assumption of the standard-addition method is not met. Therefore, the multi-point combined internal-standard standard-addition method based on the power-type calibration curve was developed and verified.
  • MALDI-TOF MS quantification is hampered by the poor reproducibility and molecular-mass and compositional discrimination. The use of an internal standard increases reproducibility and allows a calibration curve to be constructed. With synthetic polymers, the method requires a polymer of the same molecular mass distribution and composition as the analyte. When the content of the precursor polymer in a modified polymer is sought, the pure precursor is usually available and the modified polymer can serve as an internal standard. The method has to be combined with that of standard addition and the precursor polymer added directly to the sample. The experiments with simulated modified polymers revealed the signal-intensity ratio not proportional to the concentrations ratio. Thus, the basic assumption of the standard-addition method is not met. Therefore, the multi-point combined internal-standard standard-addition method based on the power-type calibration curve was developed and verified. (en)
Title
  • Quantification in MALDI-TOF mass spectrometry of modified polymers
  • Quantification in MALDI-TOF mass spectrometry of modified polymers (en)
skos:prefLabel
  • Quantification in MALDI-TOF mass spectrometry of modified polymers
  • Quantification in MALDI-TOF mass spectrometry of modified polymers (en)
skos:notation
  • RIV/61389013:_____/11:00359037!RIV12-AV0-61389013
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(GA203/08/0543), Z(AV0Z40500505)
http://linked.open...iv/cisloPeriodika
  • 1/2
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 225401
http://linked.open...ai/riv/idVysledku
  • RIV/61389013:_____/11:00359037
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • MALDI-TOF mass spectrometry; modified polymers; quantification (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [25FB3C8543A0]
http://linked.open...i/riv/nazevZdroje
  • Analytica Chimica Acta
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 693
http://linked.open...iv/tvurceVysledku
  • Horský, Jiří
  • Walterová, Zuzana
http://linked.open...ain/vavai/riv/wos
  • 000290886800010
http://linked.open...n/vavai/riv/zamer
issn
  • 0003-2670
number of pages
http://bibframe.org/vocab/doi
  • 10.1016/j.aca.2011.03.019
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 44 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software