About: A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Ambient dose-equivalent results from an in-flight comparison between different tissue-equivalent proportional counters and silicon diode spectrometers from seven European institutes are presented and compared with calculations using the EPCARD computer program. The measurements were performed on 40 000 and 32 000 ft in narrow target areas at latitudes N57 and N42. Keeping the altitude and geographic position almost constant provided unique conditions for comparisons. It is concluded that the standard deviation between different instruments can through optimization and harmonization of the calibration procedures be reduced by up to a factor of two.
  • Ambient dose-equivalent results from an in-flight comparison between different tissue-equivalent proportional counters and silicon diode spectrometers from seven European institutes are presented and compared with calculations using the EPCARD computer program. The measurements were performed on 40 000 and 32 000 ft in narrow target areas at latitudes N57 and N42. Keeping the altitude and geographic position almost constant provided unique conditions for comparisons. It is concluded that the standard deviation between different instruments can through optimization and harmonization of the calibration procedures be reduced by up to a factor of two. (en)
  • Jsou srovnány výsledky měření prostorového dávkového ekvivalentu pomocí tkániekvivalentních proporcionálních počítačů a křemíkového spektrometru s výsledky výpočtů programem EPCARD. Měření byla provedena ve dvou výškách 32 a 40 tisíc stop v úzkých pásech geomagnetických podmínek, tj. za téměř konstantních podmínkek. Bylo zjištěno, že standardní odchylky mezi různými přístroji lze optimalizací a harmonizací kalibračních procedur snížit až dvakrát. (cs)
Title
  • A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions
  • Srovnání výsledků měření pomocí přístrojů měřících prostorový dávkový ekvivalent a výsledků výpočtu za konstantních letových podmínek (cs)
  • A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions (en)
skos:prefLabel
  • A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions
  • Srovnání výsledků měření pomocí přístrojů měřících prostorový dávkový ekvivalent a výsledků výpočtu za konstantních letových podmínek (cs)
  • A comparison of ambient dose equivalent meters and dose calculations at constant flight conditions (en)
skos:notation
  • RIV/61389005:_____/07:00054659!RIV08-AV0-61389005
http://linked.open.../vavai/riv/strany
  • 323;333
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1P05OC032), Z(AV0Z10480505)
http://linked.open...iv/cisloPeriodika
  • 3
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 407819
http://linked.open...ai/riv/idVysledku
  • RIV/61389005:_____/07:00054659
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • aircrew exposure; cosmic radiation; TEPC (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [2F309888718F]
http://linked.open...i/riv/nazevZdroje
  • Radiation Measurements
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 42
http://linked.open...iv/tvurceVysledku
  • Roth, J.
  • Spurný, František
  • Beck, P.
  • Trompier, F.
  • Latocha, M.
  • Roos, H.
  • Bottollier-Depois, J. F.
  • Wissman, F.
  • Lindborg, L.
  • Schraube, H.
  • Lillhök, J.
  • Stehno, G.
http://linked.open...n/vavai/riv/zamer
issn
  • 1350-4487
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software