About: Selected ion flow tube mass spectrometry of exhaled breath condensate headspace     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples.
  • Collection of exhaled breath condensate (EBC) is a relatively simple noninvasive method of breath analysis; however, no data have been reported that would relate concentration of volatile compounds in EBC to their gaseous concentrations in exhaled air. The aim of the study was to investigate which volatile compounds are present in EBC and how their concentrations relate to results of direct breath analysis. Thus, samples of EBC were collected in a standard way from several subjects and absolute levels of several common volatile breath metabolites (ammonia, acetone, ethanol, methanol, propanol, isoprene, hydrogen cyanide, formaldehyde and acetaldehyde) were then determined in their headspace using selected ion flow tube mass spectrometry (SIFT-MS). Results are compared with those from on-line breath analyses carried out immediately before collecting the EBC samples. (en)
  • Odběr kondenzátu vydechovaného vzduchu představuje relativně jednoduchou a neinvazivní metodu pro analýzu dechu. Doposud nebyly k disposici žádné údaje dávájící do souvislosti koncentrace těkavých látek přítomných v kondenzátu a jejich koncentrace přímo ve vydechovaném vzduchu. Cílem této studie bylo prozkoumat jaké těkavé látky jsou v kondenzátu obsaženy a do jaké míry jejich koncentrace odpovídají výsledkům přímé analýzy dechu. Vzorky kondenzátu byly získány standardním způsobem pro skupinu pacientů a koncentrace čpavku, acetonu, ethanolu, methanolu, propanolu, isoprénu , kyanovodíku formaldehydu a acetaldehydu byly určeny v jejich výparech a porovnány s jejich přímým měřením v dechu bezprostředně před odběrem kondenzátu. Bylo tak prokázáno že hmotnostní spektrometrie v proudové trubici s vybranými ionty (SIFT-MS) je použitelná pro analýzu těkavých složek kondenzátu vydechovaného vzduchu a že koncentrace metanolu, čpavku, acetaldehydu a acetonu korelují s přímo měřenými hodnotami. (cs)
Title
  • Selected ion flow tube mass spectrometry of exhaled breath condensate headspace
  • Hmotnostní spektrometrie v proudové trubici s vybranými ionty (SIFT-MS) kondenzátu vydechovaného vzduchu (cs)
  • Selected ion flow tube mass spectrometry of exhaled breath condensate headspace (en)
skos:prefLabel
  • Selected ion flow tube mass spectrometry of exhaled breath condensate headspace
  • Hmotnostní spektrometrie v proudové trubici s vybranými ionty (SIFT-MS) kondenzátu vydechovaného vzduchu (cs)
  • Selected ion flow tube mass spectrometry of exhaled breath condensate headspace (en)
skos:notation
  • RIV/61388955:_____/08:00314983!RIV09-AV0-61388955
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • V, Z(AV0Z40400503)
http://linked.open...iv/cisloPeriodika
  • 18
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 394142
http://linked.open...ai/riv/idVysledku
  • RIV/61388955:_____/08:00314983
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • EBC; SIFT-MS (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [4436AD8A718F]
http://linked.open...i/riv/nazevZdroje
  • Rapid Communications in Mass Spectrometry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 22
http://linked.open...iv/tvurceVysledku
  • Dryahina, Kseniya
  • Španěl, Patrik
  • Čáp, P.
  • Pehal, F.
http://linked.open...ain/vavai/riv/wos
  • 000259738700012
http://linked.open...n/vavai/riv/zamer
issn
  • 0951-4198
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 85 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software