  • The intensity distribution of the ultrasonic energy is, after the frequency, the most significant parameter to characterize ultrasonic fields in any sonochemical experiment. Whereas in the case of low intensity ultrasound the measurement of intensity and its distribution is well solved, in the case of high intensity (when cavitation takes place) the measurement is much more complicated. That is why the predicting the acoustic pressure distribution within the cell is desirable. A numerical solution of the wave equation gave the distribution of intensity within the cell. The calculations together with experimental verification have shown that the whole reactor behaves like a resonator and the energy distribution depends strongly on its shape.
  • The intensity distribution of the ultrasonic energy is, after the frequency, the most significant parameter to characterize ultrasonic fields in any sonochemical experiment. Whereas in the case of low intensity ultrasound the measurement of intensity and its distribution is well solved, in the case of high intensity (when cavitation takes place) the measurement is much more complicated. That is why the predicting the acoustic pressure distribution within the cell is desirable. A numerical solution of the wave equation gave the distribution of intensity within the cell. The calculations together with experimental verification have shown that the whole reactor behaves like a resonator and the energy distribution depends strongly on its shape. (en)
  • Rozložení intensity ultrazvukové energie je, vedle frekvence, nejdůležitějším parametrem charakterizujícím ultrazvukové pole při sonochemickém experimentu. Zatímco v případě ultrazvuku nízké intenzity je měření této intenzity a jejího rozložení dobře vyřešeno, v případě vysoké intenzity (když dochází ke kavitaci) je měření daleko komplikovanější. To je důvod, proč předpovězení rozložení akustického tlaku po nádobce je žádoucí. Numerické řešení vlnové rovnice poskytne rozložení intenzity v cele. Výpočty spolu s experimentální verifikací ukázaly, že celý reaktor se chová jako resonátor, a že rozložení energie silně závisí na jeho tvaru. (cs)
Title
  • Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results
  • Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results (en)
  • Optimalizace geometrie 20kHz sonoreaktoru na základě numerické simulace lokálního rozložení intensity a kvalitativní porovnání výpočtu s experimentálními výsledky (cs)
skos:prefLabel
  • Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results
  • Optimisation of 20 kHz sonoreactor geometry on the basis of numerical simulation of local ultrasonic intensity and qualitative comparison with experimental results (en)
  • Optimalizace geometrie 20kHz sonoreaktoru na základě numerické simulace lokálního rozložení intensity a kvalitativní porovnání výpočtu s experimentálními výsledky (cs)
skos:notation
  • RIV/61388955:_____/07:00081091!RIV07-AV0-61388955
http://linked.open.../vavai/riv/strany
  • 19;28
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1P05OC074), P(IAA4040304), P(OC D32.001), Z(AV0Z40400503)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 439857
http://linked.open...ai/riv/idVysledku
  • RIV/61388955:_____/07:00081091
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ultrasound; intensity distribution; cell geometry optimisation; wave equation (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • NL - Nizozemsko
http://linked.open...ontrolniKodProRIV
  • [98B2EE8091A6]
http://linked.open...i/riv/nazevZdroje
  • Ultrasonics Sonochemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 14
http://linked.open...iv/tvurceVysledku
  • Klíma, Jiří
  • Ludvík, Jiří
  • González-Garcia, J.
  • Sáez, V.
  • Frias-Ferrer, A.
  • Iniesta, J.
http://linked.open...n/vavai/riv/zamer
issn
  • 1350-4177
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 117 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software