About: A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Thirty volunteers (19 males, 11 females) were recruited for a 6-month study of the volatile compounds in their exhaled breath using the selected ion flow tube mass spectrometry (SIFT-MS) analytical technique. Volunteers provided weekly breath samples between 8:45 am and I pm (before lunch), and the concentrations of several trace compounds were obtained. In this paper, we focus on the isoprene in alveolar breath, which was monitored by SIFT-MS using NO+ precursor ions. The mean isoprene level for all samples was 118 parts per billion (ppb) with a standard deviation of 68 ppb and the range of values for breath samples given is 0-474 ppb. Variability in isoprene levels was similar in most volunteers. Isoprene levels increased immediately after moderate exercise, but returned to normal within 2-3 min for those few volunteers that were investigated. Cholesterol levels analysed for only three of the subjects were not obviously correlated with isoprene concentration in breath.
  • Thirty volunteers (19 males, 11 females) were recruited for a 6-month study of the volatile compounds in their exhaled breath using the selected ion flow tube mass spectrometry (SIFT-MS) analytical technique. Volunteers provided weekly breath samples between 8:45 am and I pm (before lunch), and the concentrations of several trace compounds were obtained. In this paper, we focus on the isoprene in alveolar breath, which was monitored by SIFT-MS using NO+ precursor ions. The mean isoprene level for all samples was 118 parts per billion (ppb) with a standard deviation of 68 ppb and the range of values for breath samples given is 0-474 ppb. Variability in isoprene levels was similar in most volunteers. Isoprene levels increased immediately after moderate exercise, but returned to normal within 2-3 min for those few volunteers that were investigated. Cholesterol levels analysed for only three of the subjects were not obviously correlated with isoprene concentration in breath. (en)
  • Hmotnostní spektrometrie v proudové trubici s vybranými ionty, SIFT-MS byla použita pro monitorování těkavých látek ve vydechovaném vzduchu 30 dobrovolníků (19 mužů, 11 žen) po dobu šesti měsíců. Dobrovolníci poskytli vzorky dechu každý týden mezi 8:45 a 13:00 vždy ale před obědem. Tento článek se zaměřuje na měření izoprénu v dechu s použitím prekurzorů NO+. Průměr měřených koncentrací byl 68 miliardtin objemu, a rozsah hodnot byl od neměřitelných hodnot do 474 miliardtin. Izoprén v dechu přímo nekoreluje s věkem pohlavím ani indexem tělěsné hmotnosti. (cs)
Title
  • A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
  • Longitudinální studie izoprénu v dechu zdravých dobrovolníků s použitím hmotnostní spektrometrie v proudové trubici s vybranými ionty (cs)
  • A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS) (en)
skos:prefLabel
  • A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS)
  • Longitudinální studie izoprénu v dechu zdravých dobrovolníků s použitím hmotnostní spektrometrie v proudové trubici s vybranými ionty (cs)
  • A longitudinal study of breath isoprene in healthy volunteers using selected ion flow tube mass spectrometry (SIFT-MS) (en)
skos:notation
  • RIV/61388955:_____/06:00078426!RIV07-AV0-61388955
http://linked.open.../vavai/riv/strany
  • 13;22
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(AV0Z40400503)
http://linked.open...iv/cisloPeriodika
  • 1
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 463564
http://linked.open...ai/riv/idVysledku
  • RIV/61388955:_____/06:00078426
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • breath analysis; metabolites; ammonia; acetone (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [219E661CCD85]
http://linked.open...i/riv/nazevZdroje
  • Physiological Measurement
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 27
http://linked.open...iv/tvurceVysledku
  • Smith, D.
  • Španěl, Patrik
  • Turner, C.
http://linked.open...n/vavai/riv/zamer
issn
  • 0967-3334
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software