About: Spontaneous breathing of heliox using a semi-closed circuit: A bench study     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • %22Introduction: The use of helium-oxygen mixture (heliox) for ventilation has an advantage in patients with obstruction of the airways. The physical properties of helium enable an easier gas flow through the airways; this enables easier breathing for the patient when compared to standard ventilation of air. A high cost of heliox falls within the factors that limit the use of heliox in clinical practice. At present, heliox is administered by use of an open circuit. The aim of this study is to propose a way of heliox administration that reduces heliox consumption but does not affect the positive heliox effects upon the airway resistance.  Methods: To minimize consumption of heliox, a semi-closed circuit has been designed. The circuit is a modification of an anesthetic circuit composed of parts with the lowest possible resistances. As any circuit has its own resistance, the evaluation of its possible negative effect upon the work of breathing of patients with exacerbation of chronic obstructive pulmonary disease (COPD) has been conducted. Results: A semi-closed circuit for heliox administration has been constructed and evaluated. The intrinsic resistance of both the inspiratory and expiratory limbs of the circuit is less than 140 Pas/l. This resistance does not represent a significant workload for a patient with COPD exacerbation whose airway resistance is 10 to 20 fold higher. Conclusions: The designed semi-closed circuit offers a potential benefit of heliox in patients with COPD exacerbation%22
  • %22Introduction: The use of helium-oxygen mixture (heliox) for ventilation has an advantage in patients with obstruction of the airways. The physical properties of helium enable an easier gas flow through the airways; this enables easier breathing for the patient when compared to standard ventilation of air. A high cost of heliox falls within the factors that limit the use of heliox in clinical practice. At present, heliox is administered by use of an open circuit. The aim of this study is to propose a way of heliox administration that reduces heliox consumption but does not affect the positive heliox effects upon the airway resistance.  Methods: To minimize consumption of heliox, a semi-closed circuit has been designed. The circuit is a modification of an anesthetic circuit composed of parts with the lowest possible resistances. As any circuit has its own resistance, the evaluation of its possible negative effect upon the work of breathing of patients with exacerbation of chronic obstructive pulmonary disease (COPD) has been conducted. Results: A semi-closed circuit for heliox administration has been constructed and evaluated. The intrinsic resistance of both the inspiratory and expiratory limbs of the circuit is less than 140 Pas/l. This resistance does not represent a significant workload for a patient with COPD exacerbation whose airway resistance is 10 to 20 fold higher. Conclusions: The designed semi-closed circuit offers a potential benefit of heliox in patients with COPD exacerbation%22 (en)
Title
  • Spontaneous breathing of heliox using a semi-closed circuit: A bench study
  • Spontaneous breathing of heliox using a semi-closed circuit: A bench study (en)
skos:prefLabel
  • Spontaneous breathing of heliox using a semi-closed circuit: A bench study
  • Spontaneous breathing of heliox using a semi-closed circuit: A bench study (en)
skos:notation
  • RIV/61383082:_____/12:#0000123!RIV13-MO0-61383082
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(NS10087), V
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 170558
http://linked.open...ai/riv/idVysledku
  • RIV/61383082:_____/12:#0000123
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Heliox; COPD; Semi-closed circuit; Airway resistance; Respiratory system (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • IT - Italská republika
http://linked.open...ontrolniKodProRIV
  • [91D6E0834148]
http://linked.open...i/riv/nazevZdroje
  • INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 35
http://linked.open...iv/tvurceVysledku
  • Roubík, Karel
  • Müller, Martin
  • Tyll, Tomáš
  • Spálený, Antonín
issn
  • 0391-3988
number of pages
http://bibframe.org/vocab/doi
  • 10.5301/ijao.5000088
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software