About: Speciation of iodine, copper, selenium, zinc and iron in human serum by on-line hyphenation of liquid chromatography and inductively coupled plasma mass spectrometry     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The on-line coupling of LC and ICP-MS was used for separation and detection of species of Cu, Fe, I, Se and Zn in human serum. It has been proved that anion exchange chromatography has a better separation capability (both intra- and inter- element) than size exclusion chromatography. The mobile phases for ion exchange chromatography consisted of Tris-HNO3 buffer and ammonium salt (nitrate, acetate or formate), the concentation of which was increased during chromatographic run. Formate was found to be the best mobile phase counter ion, which enables good chromatographic separation and also is acceptable for mass spectrometer. The quantitative evaluation of cencentration of elements adherents to individual detected species fractions was performed by peakˇs area normalisation method. The repeatability of results lies in range 3 - 15% representing the main part of result uncertainty. The accuracy of Cu and Zn fractions determination was confirmed by comparison with isotope dilution technique. The results (en)
  • On-line spojení LC a ICP-MS bylo využito pro separaci a detekci specií Cu, Fe, I, Se a Zn v íidském krevním séru. Bylo vyzkoušeno, že aniontově výměnná chromatografie má lepší separační schopnost (posouzení rozdělení specíí jednoho prvku i specií různýchprvků) než gelová permeační chromatografie. Mobilní fáze pro iontově výměnnou chromatografie obsahovala pufr TRIS-HNO3(pH 7,4) a amonnou sůl (dusičnan, octan nebo mravenčan), jejíž koncentrace vzrůstala během chromatografické analýzy. Mravenčan byl shle dán jako nejlepší protion, vykazuje nejlepší chromatografické dělení a je akceptovatelný pro hmotnostní spektrometr. Kvantifikace prvků sprajých s jednotlivými detekovanými frakcemi specií byla provedena metodou vnitřní normalizace piků. Opakovatelnost výsledků leží v rozsahu 3 . 15 % a reprezentuje hlavní složku nejistoty. Přesnost stanovení Cu a Zn frakcí byla ověřena srovnáním s výsledky získanámi měřením metodou isotopového zřeďování. Dobrá shoda obou kvantifikačních technik byla získána pro výsledk
Title
  • Speciation of iodine, copper, selenium, zinc and iron in human serum by on-line hyphenation of liquid chromatography and inductively coupled plasma mass spectrometry (en)
  • Speciace jódu, mědi, selenu, zinku a železa v lidském séru pomocí spojení kapalinové chromatografie a hmotnostní spektrometrie s indukčně výzaným plazmatem
  • Speciace jódu, mědi, selenu, zinku a železa v lidském séru pomocí spojení kapalinové chromatografie a hmotnostní spektrometrie s indukčně výzaným plazmatem (cs)
skos:prefLabel
  • Speciation of iodine, copper, selenium, zinc and iron in human serum by on-line hyphenation of liquid chromatography and inductively coupled plasma mass spectrometry (en)
  • Speciace jódu, mědi, selenu, zinku a železa v lidském séru pomocí spojení kapalinové chromatografie a hmotnostní spektrometrie s indukčně výzaným plazmatem
  • Speciace jódu, mědi, selenu, zinku a železa v lidském séru pomocí spojení kapalinové chromatografie a hmotnostní spektrometrie s indukčně výzaným plazmatem (cs)
skos:notation
  • RIV/60461373:22330/03:00007510!RIV/2004/MSM/223304/N
http://linked.open.../vavai/riv/strany
  • 58-67
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • Z(MSM 223400008)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 628047
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22330/03:00007510
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Serum; Trace Elements; Metalloproteins; Ion Exchange Chromatography; Inductively Coupled Plasma Spectrometry (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [CA22C2E92A14]
http://linked.open...v/mistoKonaniAkce
  • Slapy
http://linked.open...i/riv/mistoVydani
  • Český Těšín
http://linked.open...i/riv/nazevZdroje
  • Sborník Mikroelementy 2003
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...ocetUcastnikuAkce
http://linked.open...nichUcastnikuAkce
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Kodíček, Milan
  • Koplík, Richard
  • Mestek, Oto
  • Komínková, Jana
  • Suchánek, Miloslav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • 2 Theta Český Těšín
https://schema.org/isbn
  • 80-86380-20-3
http://localhost/t...ganizacniJednotka
  • 22330
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 41 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software