About: Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • At the present time when requirements on quality of drinking water are increased, it is necessary not only to put stress on technological processes used in its preparation, but also there is a need to secure that water is distributed even to the consumer in that quality as it leaves a water station. Through a systematic surveillance of water-supply companies within the framework of biological audits it has been found out that the important points in a distribution network where the quality of water is deteriorated are the water reservoirs. Deterioration in quality of accumulated water is jointly caused by elements of technological, constructional and biological nature. The secondary air contamination has a substantial influence on the creation of biofilms on walls and the presence of microorganisms in accumulated drinking water. To this end, a water twin-compartment reservoir has been systematically evaluated during operation, cleaning meantime and before cleaning. The results of hydrobiological and microbiological analysis have confirmed the input of particles and microorganisms through air, their presence in surface level of accumulated water as well as scrapings from accumulation walls. The surveillance considered also the situation without a fixed filter unit, without door lining etc. On fixing a tested filter system into ventilation duct the risk of air contamination was lowered to minimum.
  • At the present time when requirements on quality of drinking water are increased, it is necessary not only to put stress on technological processes used in its preparation, but also there is a need to secure that water is distributed even to the consumer in that quality as it leaves a water station. Through a systematic surveillance of water-supply companies within the framework of biological audits it has been found out that the important points in a distribution network where the quality of water is deteriorated are the water reservoirs. Deterioration in quality of accumulated water is jointly caused by elements of technological, constructional and biological nature. The secondary air contamination has a substantial influence on the creation of biofilms on walls and the presence of microorganisms in accumulated drinking water. To this end, a water twin-compartment reservoir has been systematically evaluated during operation, cleaning meantime and before cleaning. The results of hydrobiological and microbiological analysis have confirmed the input of particles and microorganisms through air, their presence in surface level of accumulated water as well as scrapings from accumulation walls. The surveillance considered also the situation without a fixed filter unit, without door lining etc. On fixing a tested filter system into ventilation duct the risk of air contamination was lowered to minimum. (en)
Title
  • Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water
  • Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water (en)
skos:prefLabel
  • Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water
  • Possible negative consequences of the secondary air contamination on the quality of accumulated drinking water (en)
skos:notation
  • RIV/60461373:22320/09:00022589!RIV13-MZE-22320___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1G58052), Z(MSM6046137308)
http://linked.open...iv/cisloPeriodika
  • 19
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 334602
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22320/09:00022589
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • waterwork plants, drinking water quality, biofilm, secondary air contamination (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • SK - Slovenská republika
http://linked.open...ontrolniKodProRIV
  • [15D58BDD35E0]
http://linked.open...i/riv/nazevZdroje
  • Acta Facultatis Ecologiae
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 2009
http://linked.open...iv/tvurceVysledku
  • Říhová-Ambrožová, Jana
http://linked.open...n/vavai/riv/zamer
issn
  • 1336-300X
number of pages
http://localhost/t...ganizacniJednotka
  • 22320
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software