About: High sensitivity electrical resistance sensors for indoor corrosion monitoring     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • It is essential that corrosion monitoring of indoor atmospheres be highly sensitive, especially when corrosion rates corresponding to the lowest standard corrosivity categories are supposed to be identified within one or a few days. The electrical resistance (ER) technique in combination with high sensitivity ER sensors enabled detection of corrosion loss on an atomic scale. The magnetron sputtering method was used to produce sensors equipped with 50 to 800 nm metallic track. The set of developed sensors represent a wide range of materials, e.g. copper, silver, iron, lead and bronze. Laboratory experiments have proven that copper and silver sensors respond to changes in relative humidity and temperature within minutes. Bronze and copper sensors are able to detect changes in concentrations of volatile organic acids, which are common pollutants of indoor atmospheres in museums.
  • It is essential that corrosion monitoring of indoor atmospheres be highly sensitive, especially when corrosion rates corresponding to the lowest standard corrosivity categories are supposed to be identified within one or a few days. The electrical resistance (ER) technique in combination with high sensitivity ER sensors enabled detection of corrosion loss on an atomic scale. The magnetron sputtering method was used to produce sensors equipped with 50 to 800 nm metallic track. The set of developed sensors represent a wide range of materials, e.g. copper, silver, iron, lead and bronze. Laboratory experiments have proven that copper and silver sensors respond to changes in relative humidity and temperature within minutes. Bronze and copper sensors are able to detect changes in concentrations of volatile organic acids, which are common pollutants of indoor atmospheres in museums. (en)
Title
  • High sensitivity electrical resistance sensors for indoor corrosion monitoring
  • High sensitivity electrical resistance sensors for indoor corrosion monitoring (en)
skos:prefLabel
  • High sensitivity electrical resistance sensors for indoor corrosion monitoring
  • High sensitivity electrical resistance sensors for indoor corrosion monitoring (en)
skos:notation
  • RIV/60461373:22310/13:43896584!RIV14-MSM-22310___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...iv/cisloPeriodika
  • 4
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 77366
http://linked.open...ai/riv/idVysledku
  • RIV/60461373:22310/13:43896584
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • water electrolyser, phosphoric acid, anodic polarization, tantalum coating (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [FB5C658374F8]
http://linked.open...i/riv/nazevZdroje
  • Corros. Eng. Sci.
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 48
http://linked.open...iv/tvurceVysledku
  • Kouřil, Milan
  • Prošek, T.
  • Scheffel, B.
  • Dubois, F.
http://linked.open...ain/vavai/riv/wos
  • 000319817200005
issn
  • 1478-422X
number of pages
http://bibframe.org/vocab/doi
  • 10.1179/1743278212Y.0000000074
http://localhost/t...ganizacniJednotka
  • 22310
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software