About: Photo-induced flow-injection determination of nitrate in water     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 µm, o.d. 720 µm). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10-10 M (S/N = 3). The linear range of the method is 2 x 10-9–1 x 10-5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method.
  • A sensitive flow-injection method for the chemiluminescent determination of ultra-low concentration of nitrate in water is presented. Nitrate is on-line photolytically converted to peroxynitrite by absorption of UV light inside of 60 mm long quartz capillary (i.d. 530 µm, o.d. 720 µm). Peroxynitrite is subsequently determined by the chemiluminescent reaction with luminol. The detection limit of nitrate is 7 x 10-10 M (S/N = 3). The linear range of the method is 2 x 10-9–1 x 10-5 M nitrate. The interference of nitrite is eliminated by its conversion to nitrogen after mixing of sample with a solution of sulfamidic acid. Other common anions do not interfere. The interference of cations is eliminated by passing the sample through a cation-exchange column. The FIA procedure allows analysing of 15 samples per hour. The method was applied to the determination of nitrate in various real water samples. The results are in good agreement with a reference ion chromatographic method. (en)
Title
  • Photo-induced flow-injection determination of nitrate in water
  • Photo-induced flow-injection determination of nitrate in water (en)
skos:prefLabel
  • Photo-induced flow-injection determination of nitrate in water
  • Photo-induced flow-injection determination of nitrate in water (en)
skos:notation
  • RIV/60162694:G42__/14:00521103!RIV15-MO0-G42_____
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • I, P(OVUOFEM200904)
http://linked.open...iv/cisloPeriodika
  • 10
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 36492
http://linked.open...ai/riv/idVysledku
  • RIV/60162694:G42__/14:00521103
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • chemiluminescence; flow injection analysis; nitrate; photo-conversion; peroxynitrite; real water samples (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • GB - Spojené království Velké Británie a Severního Irska
http://linked.open...ontrolniKodProRIV
  • [0E5A5A173531]
http://linked.open...i/riv/nazevZdroje
  • International Journal of Environmental Analytical Chemistry
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 94
http://linked.open...iv/tvurceVysledku
  • Kellner, Josef
  • Mikuška, Pavel
  • Večeřa, Zbyněk
  • Čapka, Lukáš
  • Kalinichenko, Ivan
issn
  • 0306-7319
number of pages
http://localhost/t...ganizacniJednotka
  • G42
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 82 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software