About: Pulsatile non-Newtonian blood flow modelling in realistic aorto-coronary bypass grafts     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Nowadays it is generally accepted that hemodynamics has significantly influence on the performance and patency of implanted bypass grafts. Present study tries to contribute to the investigation of graft failures by modelling pulsatile non-Newtonian blood flow in three realistic aorto-coronary bypass models and by analysing the distribution of hemodynamically significant factors such as wall shear stress (WSS) and oscillatory shear index (OSI).
  • Nowadays it is generally accepted that hemodynamics has significantly influence on the performance and patency of implanted bypass grafts. Present study tries to contribute to the investigation of graft failures by modelling pulsatile non-Newtonian blood flow in three realistic aorto-coronary bypass models and by analysing the distribution of hemodynamically significant factors such as wall shear stress (WSS) and oscillatory shear index (OSI). (en)
Title
  • Pulsatile non-Newtonian blood flow modelling in realistic aorto-coronary bypass grafts
  • Pulsatile non-Newtonian blood flow modelling in realistic aorto-coronary bypass grafts (en)
skos:prefLabel
  • Pulsatile non-Newtonian blood flow modelling in realistic aorto-coronary bypass grafts
  • Pulsatile non-Newtonian blood flow modelling in realistic aorto-coronary bypass grafts (en)
skos:notation
  • RIV/49777513:23520/12:43915392!RIV13-MSM-23520___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0090)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 163616
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23520/12:43915392
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • aorto-coronary bypass, non-Newtonian fluid, fractional step method, finite volume method (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [7812D344C7AD]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Bublík, Ondřej
  • Jonášová, Alena
  • Vimmr, Jan
http://localhost/t...ganizacniJednotka
  • 23520
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software