About: Medium-voltage drive fan save : energy efficient fan systems in power engineering. Part 2, Variable pitch flow control versus variable speed flow control     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • Fan systems, pump systems and compressed air systems consume approximately 60% of total electricity generated worldwide. These systems have very significant cost-effective energy saving potential and/or CO2 reduction potential. However, the major barriers preventing to use this potential are i) no simple pattern for general solution - the need of sophisticated individual evaluation of each application for concrete facilities, and ii) the lack of methodology and/or tools that would be able to sufficiently and reliably quantify the real energy saving potential for the most suitable technology both from technological and economical point of view. In this paper, we present the results of research project which is intended to overcome these barriers. It is introduced the developed software tool, methodology and physical background for modeling of high-power industrial fan systems. By specific, we have focused on evaluation and comparison of axial-type fan in the configuration with fixed speed drive and variable pitch flow control and in the configuration with variable speed drive (VSD) and/or flow control which are directly competing technologies for energy-efficient flow control. Comparison was performed on a case study of a fan for cooling towers in thermal and/or nuclear power plants. In addition, we have attached comparisons to conventional flow control methods employing axial type of fans.
  • Fan systems, pump systems and compressed air systems consume approximately 60% of total electricity generated worldwide. These systems have very significant cost-effective energy saving potential and/or CO2 reduction potential. However, the major barriers preventing to use this potential are i) no simple pattern for general solution - the need of sophisticated individual evaluation of each application for concrete facilities, and ii) the lack of methodology and/or tools that would be able to sufficiently and reliably quantify the real energy saving potential for the most suitable technology both from technological and economical point of view. In this paper, we present the results of research project which is intended to overcome these barriers. It is introduced the developed software tool, methodology and physical background for modeling of high-power industrial fan systems. By specific, we have focused on evaluation and comparison of axial-type fan in the configuration with fixed speed drive and variable pitch flow control and in the configuration with variable speed drive (VSD) and/or flow control which are directly competing technologies for energy-efficient flow control. Comparison was performed on a case study of a fan for cooling towers in thermal and/or nuclear power plants. In addition, we have attached comparisons to conventional flow control methods employing axial type of fans. (en)
Title
  • Medium-voltage drive fan save : energy efficient fan systems in power engineering. Part 2, Variable pitch flow control versus variable speed flow control
  • Medium-voltage drive fan save : energy efficient fan systems in power engineering. Part 2, Variable pitch flow control versus variable speed flow control (en)
skos:prefLabel
  • Medium-voltage drive fan save : energy efficient fan systems in power engineering. Part 2, Variable pitch flow control versus variable speed flow control
  • Medium-voltage drive fan save : energy efficient fan systems in power engineering. Part 2, Variable pitch flow control versus variable speed flow control (en)
skos:notation
  • RIV/49777513:23220/13:43920312!RIV14-TA0-23220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED2.1.00/03.0094), P(TE01020455), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 87134
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/13:43920312
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • fan sytems, pneumatic systems, industrial application, variable speed drive, variable pitch control, variable speed control, axial fan, energy efficiency, flow control optimization, cooling tower, power plant (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [91C5AB6BA37E]
http://linked.open...v/mistoKonaniAkce
  • Vienna
http://linked.open...i/riv/mistoVydani
  • New York
http://linked.open...i/riv/nazevZdroje
  • Proceedings of IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Michalík, Jan
  • Peroutka, Zdeněk
  • Sirový, Martin
  • Byrtus, Miroslav
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
issn
  • 1553-572X
number of pages
http://bibframe.org/vocab/doi
  • 10.1109/IECON.2013.6699454
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 978-1-4799-0224-8
http://localhost/t...ganizacniJednotka
  • 23220
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software