About: Special cases of short circuit disturbed breaking by generator circuit breaker     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The paper is focused on some special cases of switching off an AC generator by SF6 circuit-breaker. Disturbed breaking of short circuit by the generator circuit breaker is analyzed and discussed. The analysis includes a description of the switching off under standard conditions, in which, during the switching process, accidentally occurs a short circuit. This switching causes shock and may lead to crashes. Therefore, new requirements on the length of the interrupting time interval are defined in comparison with the previous standard. The accident occurred especially when switching asymmetrical short circuit fault current. The paper describes the requirements for reliable switch off under discussed extraordinary conditions. (en)
  • Příspěvek je zaměřen na analýzu vypínání zkratu generátorový vypínačem (SF6) při mimořádných stavech, tzv. narušeného vypínání zkratů. Analýza obsahuje popis vypínání za normálních podmínek, při němž náhodně vznikne zkrat. Toto vypínání vyvolá rázy a může vést k havárii. Zvláště při vypínání nesymetrických zkratů se tyto havárie v některých případech vyskytly. Proto se nově vyžaduje, oproti dosavadnímu standardu, definovat délky doby vypínacího intervalu. Příspěvek popisuje spektrum požadavků na dimenzování vypínače pro spolehlivé vypínání pro tyto mimořádné stavy.
  • Příspěvek je zaměřen na analýzu vypínání zkratu generátorový vypínačem (SF6) při mimořádných stavech, tzv. narušeného vypínání zkratů. Analýza obsahuje popis vypínání za normálních podmínek, při němž náhodně vznikne zkrat. Toto vypínání vyvolá rázy a může vést k havárii. Zvláště při vypínání nesymetrických zkratů se tyto havárie v některých případech vyskytly. Proto se nově vyžaduje, oproti dosavadnímu standardu, definovat délky doby vypínacího intervalu. Příspěvek popisuje spektrum požadavků na dimenzování vypínače pro spolehlivé vypínání pro tyto mimořádné stavy. (cs)
Title
  • Special cases of short circuit disturbed breaking by generator circuit breaker (en)
  • Mimořádné podmínky narušeného vypínání zkratů generátorovým vypínačem
  • Mimořádné podmínky narušeného vypínání zkratů generátorovým vypínačem (cs)
skos:prefLabel
  • Special cases of short circuit disturbed breaking by generator circuit breaker (en)
  • Mimořádné podmínky narušeného vypínání zkratů generátorovým vypínačem
  • Mimořádné podmínky narušeného vypínání zkratů generátorovým vypínačem (cs)
skos:notation
  • RIV/49777513:23220/11:43897098!RIV12-MSM-23220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(1M06059), P(ED2.1.00/03.0094)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 212571
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/11:43897098
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • generator circuit-breaker, short circuit switch off, special case, interrupting interval, reliability. (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [F4D824EA94E4]
http://linked.open...v/mistoKonaniAkce
  • Srní
http://linked.open...i/riv/mistoVydani
  • Plzeň
http://linked.open...i/riv/nazevZdroje
  • Zvyšování životnosti komponent energetických zařízení
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Sedláček, Jan
  • Vostracký, Zdeněk
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • Západočeská univerzita v Plzni
https://schema.org/isbn
  • 978-80-261-0031-7
http://localhost/t...ganizacniJednotka
  • 23220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software