About: Aging of High Voltage Cables by Switching Impulse     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The electric ship distribution lines supply various capacitive and inductive loads that must be switched in and out of the electrical power system. These loads result in the cables being exposed to overvoltages caused by switching operation The goal is to determine the reliability of high voltage cables when they are over-stressed by a multitude of switching impulses. The presented study involves the aging of high voltage EPR and XLPE cables by applied switching impulses. Partial discharge and ac breakdown voltage were chosen as the parameters to evaluate the status of the cable.
  • The electric ship distribution lines supply various capacitive and inductive loads that must be switched in and out of the electrical power system. These loads result in the cables being exposed to overvoltages caused by switching operation The goal is to determine the reliability of high voltage cables when they are over-stressed by a multitude of switching impulses. The presented study involves the aging of high voltage EPR and XLPE cables by applied switching impulses. Partial discharge and ac breakdown voltage were chosen as the parameters to evaluate the status of the cable. (en)
  • Rozvodná síť na lodi napájí množství kapacitních a induktívních zátěží. Ty jsou připojovány i odpojovány od rozvodné sítě což způsobuje přechodové jevy jimiž jsou vysokonapě´tové kabely vystaveny. Cílem výzkumu je určit spolehlivost vysokonapěťový kabelů použitých na lodi za extrémních podmínek. (cs)
Title
  • Aging of High Voltage Cables by Switching Impulse
  • Aging of High Voltage Cables by Switching Impulse (en)
  • Stárnutí vysokonapěťových kabelů spínacími impulzy (cs)
skos:prefLabel
  • Aging of High Voltage Cables by Switching Impulse
  • Aging of High Voltage Cables by Switching Impulse (en)
  • Stárnutí vysokonapěťových kabelů spínacími impulzy (cs)
skos:notation
  • RIV/49777513:23220/07:00000140!RIV08-MSM-23220___
http://linked.open.../vavai/riv/strany
  • 165-168
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 408765
http://linked.open...ai/riv/idVysledku
  • RIV/49777513:23220/07:00000140
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • aging; dielectric breakdown voltage; high voltage cable; partial discharges; switching impulse (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [A60A904E556F]
http://linked.open...v/mistoKonaniAkce
  • Arlington, VA
http://linked.open...i/riv/mistoVydani
  • New York
http://linked.open...i/riv/nazevZdroje
  • Electric Ship Technologies Symposium
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Trnka, Pavel
  • Fulper, Jacob C.
  • Grzybowski, Stan
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
number of pages
http://purl.org/ne...btex#hasPublisher
  • IEEE
https://schema.org/isbn
  • 1-4244-0947-0
http://localhost/t...ganizacniJednotka
  • 23220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software