About: Effect of different extenders on ram sperm traits during storage     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • The aim of the study was to test commercial extenders used for short-term and long-term sperm preservation. Semen was collected in the reproduction season, i.e. from June to December. The ejaculates were obtained from single services and the routine analysis of the semen was performed immediately after the collection. The examination included semen volume, colour and texture, sperm concentration and motility, ejaculate turbulence and percentage of sperm with abnormal morphology. The semen was diluted with an extender in the ratio of 1:4. The processed semen was transported in an insulated container at 16–18 °C to the laboratory and stored in a stationary thermostat under the same temperature. Sperm motility tests were performed 24, 48, 72 and 96 hours after the placement in to thermostat. Ejaculates diluted with Ovipro, Optidyl, Triladyl and Andromed CSS gave very good results of viability (81.23 %–83.41 %) after 24 hours of storage. After 48 hours, Ovipro, Andromed, Optidyl and Triladyl gave values above 75 %. The Triladyl extender proved to be a good stabilizing agent, showing consistent results during a long-term storage. It was chosen as a control one for overall assessment. Other preservation media did not show any improving or worsening effects. The extender Ovipro showed a high motility effect in the first 48 hours only, and hence it appears to be the best solution for the short-term preservation.
  • The aim of the study was to test commercial extenders used for short-term and long-term sperm preservation. Semen was collected in the reproduction season, i.e. from June to December. The ejaculates were obtained from single services and the routine analysis of the semen was performed immediately after the collection. The examination included semen volume, colour and texture, sperm concentration and motility, ejaculate turbulence and percentage of sperm with abnormal morphology. The semen was diluted with an extender in the ratio of 1:4. The processed semen was transported in an insulated container at 16–18 °C to the laboratory and stored in a stationary thermostat under the same temperature. Sperm motility tests were performed 24, 48, 72 and 96 hours after the placement in to thermostat. Ejaculates diluted with Ovipro, Optidyl, Triladyl and Andromed CSS gave very good results of viability (81.23 %–83.41 %) after 24 hours of storage. After 48 hours, Ovipro, Andromed, Optidyl and Triladyl gave values above 75 %. The Triladyl extender proved to be a good stabilizing agent, showing consistent results during a long-term storage. It was chosen as a control one for overall assessment. Other preservation media did not show any improving or worsening effects. The extender Ovipro showed a high motility effect in the first 48 hours only, and hence it appears to be the best solution for the short-term preservation. (en)
Title
  • Effect of different extenders on ram sperm traits during storage
  • Effect of different extenders on ram sperm traits during storage (en)
skos:prefLabel
  • Effect of different extenders on ram sperm traits during storage
  • Effect of different extenders on ram sperm traits during storage (en)
skos:notation
  • RIV/49608851:_____/12:#0000580!RIV13-MZE-49608851
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(QH81324)
http://linked.open...iv/cisloPeriodika
  • 6
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 132993
http://linked.open...ai/riv/idVysledku
  • RIV/49608851:_____/12:#0000580
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • ram; sperm activity; extender (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • CZ - Česká republika
http://linked.open...ontrolniKodProRIV
  • [346C2271BB55]
http://linked.open...i/riv/nazevZdroje
  • Acta Universitatis Agriculturae et Silviculturae Mendelianae Brunensis
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • LX
http://linked.open...iv/tvurceVysledku
  • Louda, František
  • Hegedüšová, Zdeňka
  • Štolc, Ladislav
  • Vejnar, Jan
  • Čunát, Libor
issn
  • 1211-8516
number of pages
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 77 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software