| - Assurance of induction systém working in compliance with operating practices requires known of its parameters, including electrical one. Unfortunately powerful high frequency power supplies are not completing regular tíevises for measurement of inductor current. Using of standard laboratory measuring instruments, in most cases, Iseither inconvenient, from technological point of view, or impossible because there are not of them. Therefore design of sensors for measurement of inductor current of powerful high frequency induction systems is necessary. Design philosophy and important characteristics of sensors for measure of current up to 1000 A at frequency 1,5 - 4,5 MHz are describes in the páper. Principles of calibration, data processing and finally the advantages and disadvantages of the structures are presented too.
- Assurance of induction systém working in compliance with operating practices requires known of its parameters, including electrical one. Unfortunately powerful high frequency power supplies are not completing regular tíevises for measurement of inductor current. Using of standard laboratory measuring instruments, in most cases, Iseither inconvenient, from technological point of view, or impossible because there are not of them. Therefore design of sensors for measurement of inductor current of powerful high frequency induction systems is necessary. Design philosophy and important characteristics of sensors for measure of current up to 1000 A at frequency 1,5 - 4,5 MHz are describes in the páper. Principles of calibration, data processing and finally the advantages and disadvantages of the structures are presented too. (en)
|
Title
| - Measurement of high frequency induction current in powerful induction systems
- Measurement of high frequency induction current in powerful induction systems (en)
|
skos:prefLabel
| - Measurement of high frequency induction current in powerful induction systems
- Measurement of high frequency induction current in powerful induction systems (en)
|
skos:notation
| - RIV/26722445:_____/13:#0000778!RIV14-MSM-26722445
|
http://linked.open...avai/predkladatel
| |
http://linked.open...avai/riv/aktivita
| |
http://linked.open...avai/riv/aktivity
| |
http://linked.open...vai/riv/dodaniDat
| |
http://linked.open...aciTvurceVysledku
| |
http://linked.open.../riv/druhVysledku
| |
http://linked.open...iv/duvernostUdaju
| |
http://linked.open...titaPredkladatele
| |
http://linked.open...dnocenehoVysledku
| |
http://linked.open...ai/riv/idVysledku
| - RIV/26722445:_____/13:#0000778
|
http://linked.open...riv/jazykVysledku
| |
http://linked.open.../riv/klicovaSlova
| - induction system; current sensor; high frequency (en)
|
http://linked.open.../riv/klicoveSlovo
| |
http://linked.open...ontrolniKodProRIV
| |
http://linked.open...v/mistoKonaniAkce
| |
http://linked.open...i/riv/mistoVydani
| |
http://linked.open...i/riv/nazevZdroje
| - Proceedings of XV. International conference %22Complex systems: control and modeling problems%22, 25.-28.06.2013, Samara, Russia
|
http://linked.open...in/vavai/riv/obor
| |
http://linked.open...ichTvurcuVysledku
| |
http://linked.open...cetTvurcuVysledku
| |
http://linked.open...vavai/riv/projekt
| |
http://linked.open...UplatneniVysledku
| |
http://linked.open...iv/tvurceVysledku
| - Poznyak, Igor
- Votava, Pavel
|
http://linked.open...vavai/riv/typAkce
| |
http://linked.open.../riv/zahajeniAkce
| |
number of pages
| |
http://purl.org/ne...btex#hasPublisher
| - Rossijskaja Akademija Nauk
|
https://schema.org/isbn
| |