About: Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • Objectives-Ultrasound has various biological effects in the human body. The effects of continuous monitoring with ultrasound (sonolysis) on vasodilatation of the radial artery were described recently. We wanted to ascertain whether similar changes in the blood flow velocity during sonolysis could also be detected in the middle cerebral artery. Methods-Fifteen healthy volunteers (6 male and 9 female; age range, 23-68 years; mean +/- SD, 47.1 +/- 15.1 years) were subjected to 1 hour of middle cerebral artery sonolysis using a diagnostic transcranial probe with a 2-MHz Doppler frequency and measurement of the blood flow velocity at 2-minute intervals. During a second session, a flow curve was recorded for 10 seconds at 2-minute intervals. The peak systolic velocity, end-diastolic velocity, mean flow velocity, pulsatility index, and resistive index were recorded during both measurements. Results-Irregular changes in the measured blood flow parameters were recorded during both sessions. Changes in particular hemodynamic parameters during both measurements were similar. The changes in the peak systolic velocity, end-diastolic velocity, mean flow velocity, pulsatility index, and resistive index were not significantly different between the two measurements (P < .05 in all cases). Conclusions-As opposed to sonolysis of the radial artery, sonolysis of the middle cerebral artery using a diagnostic 2-MHz frequency in healthy volunteers did not lead to changes in the flow curve or peripheral vasodilatation.
  • Objectives-Ultrasound has various biological effects in the human body. The effects of continuous monitoring with ultrasound (sonolysis) on vasodilatation of the radial artery were described recently. We wanted to ascertain whether similar changes in the blood flow velocity during sonolysis could also be detected in the middle cerebral artery. Methods-Fifteen healthy volunteers (6 male and 9 female; age range, 23-68 years; mean +/- SD, 47.1 +/- 15.1 years) were subjected to 1 hour of middle cerebral artery sonolysis using a diagnostic transcranial probe with a 2-MHz Doppler frequency and measurement of the blood flow velocity at 2-minute intervals. During a second session, a flow curve was recorded for 10 seconds at 2-minute intervals. The peak systolic velocity, end-diastolic velocity, mean flow velocity, pulsatility index, and resistive index were recorded during both measurements. Results-Irregular changes in the measured blood flow parameters were recorded during both sessions. Changes in particular hemodynamic parameters during both measurements were similar. The changes in the peak systolic velocity, end-diastolic velocity, mean flow velocity, pulsatility index, and resistive index were not significantly different between the two measurements (P < .05 in all cases). Conclusions-As opposed to sonolysis of the radial artery, sonolysis of the middle cerebral artery using a diagnostic 2-MHz frequency in healthy volunteers did not lead to changes in the flow curve or peripheral vasodilatation. (en)
Title
  • Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers
  • Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers (en)
skos:prefLabel
  • Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers
  • Changes in middle cerebral artery blood flow velocity during sonolysis using a diagnostic transcranial probe with a 2-MHz doppler frequency in healthy volunteers (en)
skos:notation
  • RIV/00843989:_____/12:00102800!RIV13-MZ0-00843989
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(NT11386)
http://linked.open...iv/cisloPeriodika
  • 11
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 126689
http://linked.open...ai/riv/idVysledku
  • RIV/00843989:_____/12:00102800
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • blood flow oscillation; sonolysis; transcranial probe; ultrasound (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...odStatuVydavatele
  • US - Spojené státy americké
http://linked.open...ontrolniKodProRIV
  • [7C611C7A8110]
http://linked.open...i/riv/nazevZdroje
  • Journal of Ultrasound in Medicine
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...v/svazekPeriodika
  • 31
http://linked.open...iv/tvurceVysledku
  • Školoudík, David
  • Kuliha, Martin
  • Langová, K.
  • Bardoň, P.
  • Herzig, R.
  • Kaňovský, P.
  • Šaňák, D.
http://linked.open...ain/vavai/riv/wos
  • 000310653000012
issn
  • 0278-4297
number of pages
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software