About: Acoustic MEMS Sensor Test Chamber     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • The chamber is used for accurate MEMS sensor acoustic response measurement during calibration measurement. Better segregation of the internal and ambient acoustic space, defined acoustic signal generation, measurement by up to 8 single channels and 1 reference calibrated channel are possible. Electronic measurement devices with PC software for automatic harmonic signal sweep are included into the measurement chamber. Automated frequency characteristics measurement of the sensors should be also realized by the software. (en)
  • Komora slouží pro přesné stanovení odezvy vyráběných MEMS senzorů na akustickou stimulaci v průběhu kalibračních měření. Umožňuje oddělení vnitřního a vnějšího akustického prostředí, generování definovaného akustického signálu, měření až osmi libovolných testovaných analogových signálů a jednoho referenčního signálu (slouží pro normalizování generovaného signálu). Součástí testovací komory je i elektronické vybavení včetně softwaru v PC pro automatické rozmítání harmonického signálu s definovanou konstantní hladinou akustického tlaku. Automatické měření frekvenčních charakteristik senzoru je realizováno také pomocí softwaru v PC.
  • Komora slouží pro přesné stanovení odezvy vyráběných MEMS senzorů na akustickou stimulaci v průběhu kalibračních měření. Umožňuje oddělení vnitřního a vnějšího akustického prostředí, generování definovaného akustického signálu, měření až osmi libovolných testovaných analogových signálů a jednoho referenčního signálu (slouží pro normalizování generovaného signálu). Součástí testovací komory je i elektronické vybavení včetně softwaru v PC pro automatické rozmítání harmonického signálu s definovanou konstantní hladinou akustického tlaku. Automatické měření frekvenčních charakteristik senzoru je realizováno také pomocí softwaru v PC. (cs)
Title
  • Acoustic MEMS Sensor Test Chamber (en)
  • Komora pro testování akustických MEMS snímačů
  • Komora pro testování akustických MEMS snímačů (cs)
skos:prefLabel
  • Acoustic MEMS Sensor Test Chamber (en)
  • Komora pro testování akustických MEMS snímačů
  • Komora pro testování akustických MEMS snímačů (cs)
skos:notation
  • RIV/00216305:26620/14:PR27206!RIV15-MSM-26620___
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(GA13-18219S), S
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • Náklady na vývoj: 20tis. Kč
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 24554
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26620/14:PR27206
http://linked.open...terniIdentifikace
  • AkuKomora
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • kochlea,MEMS sensor,acoustic test chamber (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [ABAC4C11A8A2]
http://linked.open.../licencniPoplatek
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • Funkční vzorek byl na základě získaných poznatků zkonstruován a ověřen. Je využíván na pracovišti řešitele LabSensNano (VUT v Brně, Fakulta elektrotechniky a komunikačních technologií, Ústav mikroelektroniky, Technická 3058/10, 616 00 Brno, Česká republika) Zařízení je určeno pro kalibraci MEMS senzorů elektronické kochley.
http://linked.open...iv/tvurceVysledku
  • Prášek, Jan
  • Sedláček, Jiří
  • Žák, Jaromír
  • Svatoš, Vojtěch
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://localhost/t...ganizacniJednotka
  • 26620
Faceted Search & Find service v1.16.116 as of Feb 22 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3239 as of Feb 22 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 67 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software