About: Microfluidic system for conductivity measurement     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
rdfs:seeAlso
Description
  • A system for measuring the conductivity in the separation mikrokanálcích. The system consists of naprášených electrodes on glass (NiCr / Au) and PDMS chip, which is removable, and fixed to a predetermined position. Outlets and voltage measuring electrodes are connected to microwires with PCB connectors. In the first step of measuring conductivity is introduced under pressure into the system buffer. In the second step, the pipette sample intended for the separation of C into the reservoir and then through a voltage source is to direct the flow of particles between reservoirs C and D. Following phase separation, which involves switching on the voltage source rezervoárům A and B. The separated substances respectively. their conductivity can then be detected by measuring up to three electrodes. (en)
  • Jedná se o systém pro měření vodivosti v separačních mikrokanálcích. Celý systém se skládá z elektrod naprášených na skle (NiCr/Au) a PDMS čipu, který je výměnný a přidělává se na předem určené místo. Vývody měřicích a napěťových elektrod jsou pomocí mikrodrátku připojeny na DPS s konektory. V prvním kroku měření vodivosti se pod tlakem zavede pufr do celého systému. V druhém kroku se napipetuje vzorek určený k separaci do rezervoáru C a poté pomocí napěťového zdroje dojde k usměrnění toku částic mezi rezervoáry C a D. Následuje fáze separace, při níž dojde k přepnutí napěťového zdroje k rezervoárům A a B. Separované látky resp. jejich vodivost lze poté detekovat pomocí až tří měřicích elektrod.
  • Jedná se o systém pro měření vodivosti v separačních mikrokanálcích. Celý systém se skládá z elektrod naprášených na skle (NiCr/Au) a PDMS čipu, který je výměnný a přidělává se na předem určené místo. Vývody měřicích a napěťových elektrod jsou pomocí mikrodrátku připojeny na DPS s konektory. V prvním kroku měření vodivosti se pod tlakem zavede pufr do celého systému. V druhém kroku se napipetuje vzorek určený k separaci do rezervoáru C a poté pomocí napěťového zdroje dojde k usměrnění toku částic mezi rezervoáry C a D. Následuje fáze separace, při níž dojde k přepnutí napěťového zdroje k rezervoárům A a B. Separované látky resp. jejich vodivost lze poté detekovat pomocí až tří měřicích elektrod. (cs)
Title
  • Microfluidic system for conductivity measurement (en)
  • Mikrofluidní systém pro měření vodivosti
  • Mikrofluidní systém pro měření vodivosti (cs)
skos:prefLabel
  • Microfluidic system for conductivity measurement (en)
  • Mikrofluidní systém pro měření vodivosti
  • Mikrofluidní systém pro měření vodivosti (cs)
skos:notation
  • RIV/00216305:26620/12:PR26319!RIV13-AV0-26620___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(ED1.1.00/02.0068), P(KAN208130801)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...onomickeParametry
  • Vývoj 10 tis. Kč, know-how 20 tis. Kč
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 150514
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26620/12:PR26319
http://linked.open...terniIdentifikace
  • MS for CM
http://linked.open...riv/jazykVysledku
http://linked.open...vai/riv/kategorie
http://linked.open.../riv/klicovaSlova
  • conductivity measurement, microfluidic (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [087E30027F34]
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...echnickeParametry
  • Funkční vzorek byl na základě získaných poznatků zkonstruován a ověřen. Je využíván na pracovišti řešitele LabSensNano (VUT v Brně, Fakulta elektrotechniky a komunikačních technologií, Ústav mikroelektroniky, Technická 3058/10, 616 00 Brno, Česká republika) Určeno pro měření vodivosti v mikrofluidních systémech. Materiál kartit, skleněná podložka s NiCr/Au elektrodami a deska plošného spoje FR4.
http://linked.open...iv/tvurceVysledku
  • Chomoucká, Jana
  • Hubálek, Jaromír
  • Kizek, René
  • Pekárek, Jan
  • Sedláček, Jiří
  • Žák, Jaromír
http://linked.open...avai/riv/vlastnik
http://linked.open...itiJinymSubjektem
http://localhost/t...ganizacniJednotka
  • 26620
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 58 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software