About: Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses     Goto   Sponge   NotDistinct   Permalink

An Entity of Type : http://linked.opendata.cz/ontology/domain/vavai/Vysledek, within Data Space : linked.opendata.cz associated with source document(s)

AttributesValues
rdf:type
Description
  • This article deals with description of limiting effects occurring by measurement of non-harmonical high-level current pulses by means of inductive sensors. These effects will be described for the case of Rogowski coil application in current pulses measurement. The first is a fact that the sensor must be considered as a circuit with distributed parameters. For measuring of non-harmonic waveforms is necessary to ensure the Heaviside's condition for distortionless transmission line. The second factor is the Gibbs's effect which causes overshoots on the edges of a rectangular pulse. The third factor is the influence of wire position in the sensor on the character of output waveform. All of these factors which have been mentioned above cause a serious limitation of induction sensor application for non-harmonic current pulses measurement. Special precautions have to be ensured in order to attain of distortion-free measurement. The influence of precaution violation on the measured waveform will be shown.
  • This article deals with description of limiting effects occurring by measurement of non-harmonical high-level current pulses by means of inductive sensors. These effects will be described for the case of Rogowski coil application in current pulses measurement. The first is a fact that the sensor must be considered as a circuit with distributed parameters. For measuring of non-harmonic waveforms is necessary to ensure the Heaviside's condition for distortionless transmission line. The second factor is the Gibbs's effect which causes overshoots on the edges of a rectangular pulse. The third factor is the influence of wire position in the sensor on the character of output waveform. All of these factors which have been mentioned above cause a serious limitation of induction sensor application for non-harmonic current pulses measurement. Special precautions have to be ensured in order to attain of distortion-free measurement. The influence of precaution violation on the measured waveform will be shown. (en)
Title
  • Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses
  • Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses (en)
skos:prefLabel
  • Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses
  • Limiting Effects in the Application of Inductive Sensors for Measuring of Non-harmonic High-level Current Pulses (en)
skos:notation
  • RIV/00216305:26220/12:PU98039!RIV13-MSM-26220___
http://linked.open...avai/predkladatel
http://linked.open...avai/riv/aktivita
http://linked.open...avai/riv/aktivity
  • P(FR-TI1/001), S, Z(MSM0021630513)
http://linked.open...vai/riv/dodaniDat
http://linked.open...aciTvurceVysledku
http://linked.open.../riv/druhVysledku
http://linked.open...iv/duvernostUdaju
http://linked.open...titaPredkladatele
http://linked.open...dnocenehoVysledku
  • 147085
http://linked.open...ai/riv/idVysledku
  • RIV/00216305:26220/12:PU98039
http://linked.open...riv/jazykVysledku
http://linked.open.../riv/klicovaSlova
  • Rogowski coil,Heaviside's condition,Gibbs's effect,non-harmonical high-level current pulses,inductive sensors (en)
http://linked.open.../riv/klicoveSlovo
http://linked.open...ontrolniKodProRIV
  • [236E09AE96EE]
http://linked.open...v/mistoKonaniAkce
  • Kuala Lumpur
http://linked.open...i/riv/mistoVydani
  • Neuveden
http://linked.open...i/riv/nazevZdroje
  • Progress in Electromagnetics Research Symposium Proceedings, KL, Malaysia
http://linked.open...in/vavai/riv/obor
http://linked.open...ichTvurcuVysledku
http://linked.open...cetTvurcuVysledku
http://linked.open...vavai/riv/projekt
http://linked.open...UplatneniVysledku
http://linked.open...iv/tvurceVysledku
  • Drexler, Petr
  • Myška, Radek
http://linked.open...vavai/riv/typAkce
http://linked.open.../riv/zahajeniAkce
http://linked.open...n/vavai/riv/zamer
number of pages
http://purl.org/ne...btex#hasPublisher
  • Neuveden
https://schema.org/isbn
  • 978-1-934142-12-7
http://localhost/t...ganizacniJednotka
  • 26220
is http://linked.open...avai/riv/vysledek of
Faceted Search & Find service v1.16.118 as of Jun 21 2024


Alternative Linked Data Documents: ODE     Content Formats:   [cxml] [csv]     RDF   [text] [turtle] [ld+json] [rdf+json] [rdf+xml]     ODATA   [atom+xml] [odata+json]     Microdata   [microdata+json] [html]    About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data] Valid XHTML + RDFa
OpenLink Virtuoso version 07.20.3240 as of Jun 21 2024, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (126 GB total memory, 112 GB memory in use)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software